Abstract
To determine the cone spacing in normal and myopic eyes from the images obtained by an adaptive optics (AO) fundus camera. Nineteen eyes of 19 healthy volunteers with a mean ± SD spherical equivalent refractive error of −3.7 ± 3.3 diopters (D) (range, −0.3 to −11.1 D) and a mean axial length of 25.4 ± 1.61 mm (range, 23.4–28.0 mm) were investigated in a prospective cross-sectional study. An AO fundus camera equipped with a liquid crystal phase modulator was used to obtain the images of the photoreceptor mosaic. The spacing between the cones was calculated manually at a retinal locus 2° temporal from the center of the fovea. The magnification of the image was calculated by the axial length measured with an IOL Master. The axial length was correlated with the refractive error (Pearson, r = −0.869; P < 0.001). The average cone spacing in the moderate- to high-myopia group (−6.5 ± 2.3 D, n = 9) was 4.71 ± 0.44 µm, which was significantly greater (P = 0.002) than the 3.90 ± 0.47 µm in the normal and low-myopia groups (−1.1 ± 0.9 D, n = 10). The cone spacing was significantly correlated with the axial length (r = 0.77, P < 0.001). The AO fundus camera is capable of acquiring images of the photoreceptors in normal and myopic eyes. The greater spacing between cones in the myopia group is consistent with histological findings. These results suggest that retinal expansion should be considered in addition to Knapp's law when aniseikonia is evaluated in axial myopia. Jpn J Ophthalmol 2007;51:456–461 © Japanese Ophthalmological Society 2007Keywords
This publication has 18 references indexed in Scilit:
- Neural and optical limits to visual performance in myopiaVision Research, 2006
- Adaptive optics flood-illumination camera for high speed retinal imagingOptics Express, 2006
- High-Resolution Retinal Imaging of Cone–Rod DystrophyOphthalmology, 2006
- Direct and Noninvasive Assessment of Parafoveal Capillary Leukocyte VelocityOphthalmology, 2005
- Organization of the Human Trichromatic Cone MosaicJournal of Neuroscience, 2005
- Retinal stretching limits peripheral visual acuity in myopiaVision Research, 2005
- Eye Shape in Emmetropia and MyopiaInvestigative Opthalmology & Visual Science, 2004
- Adaptive optics with a programmable phase modulator: applications in the human eyeOptics Express, 2004
- PATHOLOGIC FINDINGS IN PATHOLOGIC MYOPIARetina, 1992
- Human photoreceptor topographyJournal of Comparative Neurology, 1990