Double average parallel steady‐state free precession imaging: Optimized eddy current and transient oscillation compensation
Open Access
- 9 September 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (4) , 965-974
- https://doi.org/10.1002/mrm.20615
Abstract
Balanced steady‐state free precession (SSFP) imaging is sensitive to off‐resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady‐state interruption. In addition, nonlinear k‐space encoding is required if contrast‐relevant k‐space regions need to be acquired at specific delays following magnetization preparation or for transient artifact reduction in cardiac‐gated k‐space segmented CINE imaging. Such trajectories are problematic for balanced SSFP imaging due to nonconstant eddy current effects and resulting disruption of the steady state.In this work, a novel acquisition strategy for balanced SSFP imaging is presented that utilizes scan time reduction by parallel imaging for optimized “double average” eddy current compensation and artifact reduction during the transient phase following steady‐state storage and magnetization preparation. Double average parallel SSFP imaging was applied to k‐space segmented CINE SSFP tagging as well as nongated centrically encoded SSFP imaging. Phantom and human studies exhibit substantial reduction in steady‐state storage and eddy current artifacts while maintaining spatial resolution, signal‐to‐noise ratio, and similar total scan time of a standard SSFP acquisition. The proposed technique can easily be extended to other acquisition schemes that would benefit from nonlinear reordering schemes and/or rely on interruption of the balanced SSFP steady state. Magn Reson Med, 2005.Keywords
This publication has 27 references indexed in Scilit:
- Principles and applications of balanced SSFP techniquesEuropean Radiology, 2003
- Signal behavior in continuously ramped 2D TrueFISP for whole-body imagingMagnetic Resonance in Medicine, 2002
- Single‐breathhold 3D‐trueFISP cine cardiac imagingMagnetic Resonance in Medicine, 2002
- High‐resolution MRI of cardiac function with projection reconstruction and steady‐state free precessionMagnetic Resonance in Medicine, 2002
- Oscillating dual-equilibrium steady-state angiography.Magnetic Resonance in Medicine, 2002
- Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricleJournal of Magnetic Resonance Imaging, 2001
- 3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteriesMagnetic Resonance in Medicine, 2001
- Magnetization preparation during the steady state: Fat‐saturated 3D TrueFISPMagnetic Resonance in Medicine, 2001
- Fluctuating equilibrium MRIMagnetic Resonance in Medicine, 1999
- Steady-State Free Precession in Nuclear Magnetic ResonancePhysical Review B, 1958