Digital Signal Processing Chip Implementation for Detection and Analysis of Intracardiac Electrograms
- 1 August 1994
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (8) , 1373-1379
- https://doi.org/10.1111/j.1540-8159.1994.tb02456.x
Abstract
The adoption of digital signal processing (DSP) microchips for detection and analysis of electrocardiographic signals offers a means for increased computational speed and the opportunity for design of customized architecture to address real‐time requirements. A system using the Motorola 56001 DSP chip has been designed to realize cycle‐by‐cycle detection (triggering) and waveform analysis using a time‐domain template matching technique, correlation waveform analysis (CWA). The system digitally samples an electrocardiographic signal at 1000 Hz, incorporates an adaptive trigger for detection of cardiac events, and classifies each waveform as normal or abnormal. Ten paired sets of single‐chamber bipolar intracardiac electrograms (1–500 Hz) were processed with each pair containing a sinus rhythm (SR) passage and a corresponding arrhythmia segment from the same patient. Four of ten paired sets contained intraatrial electrograms that exhibited retrograde atrial conduction during ventricular pacing; the remaining six paired sets of intraventricular electrograms consisted of either ventricular tachycardia (4) or paced ventricular rhythm (2). Of 2,978 depolarizations in the test set, the adaptive trigger failed to detect 6 (99.8% detection sensitivity) and had 11 false triggers (99.6% specificity). Using patient dependent thresholds for CWA to classify waveforms, the program correctly identified 1,175 of 1,197 (98.2% specificity) sinus rhythm depolarizations and 1,771 of 1.781 (99.4% sensitivity) abnormal depolarizations. From the results, the algorithm appears to hold potential for applications such as realtime monitoring of electrophysiology studies or detection and classification of tachycardias in implantable antitachycardia devices.Keywords
This publication has 9 references indexed in Scilit:
- Real‐Time Arrhythmia Identification from Automated Analysis of Intraatrial and Intraventricular ElectrogramsPacing and Clinical Electrophysiology, 1993
- An Innovative Two-Channel Rate And Morphology Method For Complex Arrhythmia Diagnosis In Implantable DevicesPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1992
- Implantable Cardioverter Defibrillator Proarrhythmia: Case Report and Review of the LiteraturePacing and Clinical Electrophysiology, 1991
- A Time‐Domain Analysis of Intracardiac Electrograms for Arrhythmia DetectionPacing and Clinical Electrophysiology, 1991
- Discrimination of Retrograde from Anterograde Atrial Activation Using Intracardiac Electrogram Waveform AnalysisPacing and Clinical Electrophysiology, 1989
- Programmable DSP architectures. IIIEEE ASSP Magazine, 1989
- Identification of Ventricular Tachycardia Using Intracavitary Ventricular Electrograms: Analysis of Time and Frequency Domain PatternsPacing and Clinical Electrophysiology, 1988
- Programmable DSP architectures. IIEEE ASSP Magazine, 1988
- Automated electrocardiography and arrhythmia monitoringProgress in Cardiovascular Diseases, 1983