Selective On-Line Preconcentration of Proteins by Tandem Metal Chelate Capillaries-Capillary Zone Electrophoresis
- 1 July 1993
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 16 (9-10) , 2007-2024
- https://doi.org/10.1080/10826079308019910
Abstract
Fused-silica capillaries having surface bound iminodiacetic acid metal chelating functions were developed for the selective on-line preconcentration of dilute protein samples prior to capillary zone electrophoresis. The metal chelate capillaries with immobilized zinc proved effective in the selective accumulation of detectable amounts of proteins from dilute samples. They permitted the detection of 25 times less concentrated samples than by CZE alone with concentration sensitive detectors. Large sample volumes could be introduced without affecting separation efficiency. Besides demonstrating the effectiveness of metal chelate capillaries in the quantitative determination of proteins from dilute samples, the effects of pH. composition of electrolytes and sample feeding time on the analytical signal were examined with carbonic anhydrase, a zinc binding protein.Keywords
This publication has 20 references indexed in Scilit:
- Field amplified sample injection in high-performance capillary electrophoresisJournal of Chromatography A, 1991
- Field-amplified polarity-switching sample injection in high-performance capillary electrophoresisJournal of Chromatography A, 1991
- Analysis of dilute peptide samples by capillary zone electrophoresisJournal of Chromatography A, 1990
- On-line isotachophoretic sample preconcentration for enhancement of zone detectability in capillary zone electrophoresisJournal of Microcolumn Separations, 1990
- Capillary zone electrophoresis of dilute samples with isotachophoretic preconcentrationJournal of Microcolumn Separations, 1990
- On-line coupling of capillary isotachophoresis with capillary zone electrophoresisJournal of Chromatography A, 1990
- Indirect fluorimetric detection and quantification in capillary zone electrophoresis of inorganic anions and necleotidesJournal of Chromatography A, 1989
- Electrophoresis in one buffer at two pH valuesElectrophoresis, 1989
- Carrier-free zone electrophoresis, displacement electrophoresis and isoelectric focusing in a high-performance electrophoresis apparatusJournal of Chromatography A, 1987
- Large sample volume preseparation for trace analysis in isotachophoresisJournal of Chromatography A, 1985