Isolations of aerobic sporing bacilli from the tips of indwelling intravascular catheters.
Open Access
- 1 February 1975
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 28 (2) , 146-148
- https://doi.org/10.1136/jcp.28.2.146
Abstract
Following previous reports of the isolation of aerobic sporing bacilli from intravenous catheters and infusion sets, it was decided to analyse a series of catheter tip cultures to ascertain the significance of these isolations. Those catheters from which aerobic sporing bacilli were isolated behaved statistically differently from other catheters from which organisms were isolated, but were statistically similar to sterile catheters. Using the nitroblue tetrazolium (NBT) test no significant difference was found between patients with isolates of aerobic sporing bacilli and those with sterile catheters. The NBT test readily distinguished those patients from whom other organisms were isolated. In a small number of instances some evidence of a possible pathogenic role for the aerobic sporing bacillus was found, but the results clearly indicate that in most cases these organisms can be regarded as contaminants.Keywords
This publication has 5 references indexed in Scilit:
- Infective complications of open-heart surgery and the monitoring of infections by the NBT testThorax, 1973
- Bacterial contamination of drip sets.1973
- Technique for the performance of the nitro-blue tetrazolium (NBT) test.Journal of Clinical Pathology, 1972
- INFECTIVE COMPLICATIONS OF INDWELLING INTRAVENOUS CATHETERS AND THE MONITORING OF INFECTIONS BY THE NITROBLUE-TETRAZOLIUM TESTThe Lancet, 1972
- Human Infections Caused by Organisms of the Bacillus SpeciesAmerican Journal of Clinical Pathology, 1970