On the management of retained airgun pellets: a survey of 11 orbital cases.
Open Access
- 1 February 1988
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 72 (2) , 97-100
- https://doi.org/10.1136/bjo.72.2.97
Abstract
Relevant factors determining the management of inaccessible retained lead airgun pellets are discussed in relation to 11 orbital cases. Although the injuries were of between one month's and 26 years' standing, serum lead levels were normal at under 350 micrograms/l in all instances. This is attributable to the modern alloy composition of the ammunition in question. It is concluded that surgical intervention may be indicated only where there is a mechanical disturbance of ocular motility allied with good visual function.This publication has 10 references indexed in Scilit:
- WHEN ARE AIRGUN PELLETS BETTER LEFT ALONE?The Lancet, 1985
- Intraorbitale, extrabulbär gelegene ProjektilverletzungenKlinische Monatsblätter für Augenheilkunde, 1980
- Lead poisoning from a gunshot woundThe American Journal of Medicine, 1979
- Pellet gun injuries of the eye.1978
- Ocular Injuries Caused by Airgun Pellets: An Analysis of 105 CasesBMJ, 1973
- [Histochemical and chemical studies on the lead toxicity of small shots in normal commercial usage].1969
- Laboratory studies on the lead poisoning in six cases with lead shot lodged in the tissues.1969
- [Histochemical, spectrum analytical and quantitative chemical lead studies of the problem of lead poisoning and buckshot injuries].1968
- [ACUTE LEAD POISONING BY LEAD SHOT WOUNDS].1965
- LEAD ABSORPTION FROM BULLETS LODGED IN TISSUESJAMA, 1940