High-Precision D/H Measurement from Organic Mixtures by Gas Chromatography Continuous-Flow Isotope Ratio Mass Spectrometry Using a Palladium Filter
- 1 September 1996
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (17) , 3002-3007
- https://doi.org/10.1021/ac960433d
Abstract
Continuous-flow high-precision determination of D/H ratios from an organic mixture is described using gas chromatography coupled to a Pd filter system as an interface for isotope ratio mass spectrometry. A gas chromatograph and combustion and reduction furnaces are connected to a Pd filter via a postcolumn head pressure makeup gas to increase chromatographic sensitivity. This interface is evaluated using benzene as an internal standard in a mixture of ethylbenzene and cyclohexanone in hexane with analyte quantities of SMOW), resulting in an average benzene D/H precision of SD SMOW) and deviations of <4‰ from the calibration curve. Ethylbenzene and cyclohexanone of a single D enrichment are analyzed as unknowns in three sample mixtures with varying D-enriched benzene and result in precisions of SD <5‰. No apparent memory is observed between peaks of differently enriched analytes within the same chromatogram. All results are corrected for ion source nonlinearities characteristic of hydrogen analysis, using the internal peakwise correction algorithm, described previously. A small dependence of isotope ratio on palladium membrane temperature is demonstrated over a range of 4 °C; therefore, with tighter control of palladium temperature, precision can probably be improved. The data indicate that this system is useful for rapid continuous-flow IRMS analysis of D/H ratios from organics in complex mixtures characteristic of geological and biological samples.Keywords
This publication has 18 references indexed in Scilit:
- High-Precision D/H Measurement from Hydrogen Gas and Water by Continuous-Flow Isotope Ratio Mass SpectrometryAnalytical Chemistry, 1995
- High-Precision Determination of 2H/1H in H2 and H2O by Continuous-Flow Isotope Ratio Mass SpectrometryAnalytical Chemistry, 1995
- High-precision gas isotope ratio mass spectrometry: recent advances in instrumentation and biomedical applicationsAccounts of Chemical Research, 1994
- Mass spectrometric analysis of stable-isotope-labelled amino acid tracersProceedings of the Nutrition Society, 1994
- High-precision liquid chromatography-combustion isotope ratio mass spectrometryAnalytical Chemistry, 1993
- Preparation of organic and water hydrogen for stable isotope analysis: effects due to reaction vessels and zinc reagentAnalytical Chemistry, 1993
- Automatic δD and δ18O analyses of multi-water samples using H2- and CO2-water equilibration methods with a common equilibration set-upInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1989
- Integration of differential pulse voltammograms for concentration measurementsAnalytical Chemistry, 1982
- A new technique for the detection of metabolites labelled by the isotope13C using mass fragmentographyJournal of Mass Spectrometry, 1976
- Palladium-hydrogen system. Efficient interface for gas chromatography-mass spectrometryAnalytical Chemistry, 1970