Construction of a hybrid quadrupole/fourier transform ion cyclotron resonance mass spectrometer for versatile MS/MS above 10 kDa
- 1 July 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 15 (7) , 1099-1108
- https://doi.org/10.1016/j.jasms.2004.04.031
Abstract
Technological advancements including an open-cylindrical Penning trap with capacitively coupled ICR cell, selective ion accumulation with a resolving quadrupole, and a voltage gradient used during ion extraction from an octopole ion trap, have individually improved dynamic range and sensitivity in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS). Documented here is a new instrument utilizing these technologies toward the robust detection and fragmentation of biomolecules >10 kDa. Up to 55-fold enhancement in ion population by selective ion accumulation combined with 10- to 20- fold signal-to-noise improvement by application of a DC voltage gradient to an accumulation octopole during the ion transfer event offers improved signal-to-noise (or speed) of MS/MS experiments, for proteins from Methanococcus jannaschii and Saccharomyces cerevisiae whole cell lysates. After external quadrupole filtering with a 40 m/z window, three proteins were fragmented (and identified) in parallel from the database of Methanococcus jannaschii. Electron capture dissociation (ECD) of an intact yeast protein provides extensive sequence information resulting in a high degree of localization for an N-terminal acetylation. Hybrid fragmentation, infrared multiphoton dissociation (IRMPD) followed by low energy electrons (ECD), with the electron source located laterally off the z-axis and external to the magnet bore, presents a strategy for identification of proteins by means of the sequence tag approach. Automated implementation of diverse MSn approaches in a Q-FTMS instrument promises to help realize “top-down” proteomics in the future.Keywords
This publication has 43 references indexed in Scilit:
- An Automated Matrix-Assisted Laser Desorption/Ionization Quadrupole Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for “Bottom-Up” ProteomicsAnalytical Chemistry, 2003
- Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: Theory and applicationsInternational Journal of Mass Spectrometry and Ion Processes, 1996
- Ultrahigh-resolution fourier transform mass spectrometry of biomolecules above m/z 5 000International Journal of Mass Spectrometry and Ion Processes, 1996
- Sequence Information from 42−108-mer DNAs (Complete for a 50-mer) by Tandem Mass SpectrometryJournal of the American Chemical Society, 1996
- Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometryPhysical Review E, 1995
- Ultrahigh‐resolution matrix‐assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectra of peptidesJournal of Mass Spectrometry, 1995
- Dynamics of ion coupling in an FTMS ion trap and resulting effects on mass spectra, including isotope ratiosInternational Journal of Mass Spectrometry and Ion Processes, 1994
- Elimination of axial ejection during excitation with a capacitively coupled open trapped-ion cell for Fourier transform ion cyclotron resonance mass spectrometryAnalytical Chemistry, 1992
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Mass-dependent z-excitation of ions in cubic traps used in FTMSInternational Journal of Mass Spectrometry and Ion Processes, 1986