The Effect of 50 Hz External Electrical Interference on Implanted Cardiac Pacemakers
- 1 July 1988
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 11 (7) , 999-1008
- https://doi.org/10.1111/j.1540-8159.1988.tb03944.x
Abstract
The effects of injected 50 Hz alternating current on the function of cardiac pacemakers has been observed in 18 patients with implanted unipolar VVI units. Current, in the range 0–600 μA was applied via electrodes attached to the patients' upper body and feet and fed from a specially designed current injection unit at the bedside. Most implanted pacemakers reverted to interference mode in the current range 29–250 μA. At current levels just below the reversion current all units developed irregular and inappropriate pacing. This current level was pacemaker dependent and varied in the range 27–246 μA. The total reversion current depended on the location of the injecting electrodes and on the patients' posture. The sensitivity of the units to injected interference was increased by deep inspiration. Temporary pacing catheters fitted to an additional ten patients were used to monitor the interference voltage which would be sensed by an implanted unit. This voltage was similarly dependent on patient posture and on deep respiration. Current injection has proved to be a safe, controllable and reproducible method of testing the sensitivity of implanted pacemakers to 50 Hz external interference.Keywords
This publication has 10 references indexed in Scilit:
- The Effect of Power Frequency High Intensity Electric Fields on Implanted Cardiac PacemakersPacing and Clinical Electrophysiology, 1983
- Unipolar Sensing Abnormalities: Incidence and Clinical Significance of Skeletal Muscle Interference and Under sensing in 228 PatientsPacing and Clinical Electrophysiology, 1982
- Bipolar Leads for Cardiac Pacing in the 1980s: A Reappraisal Provoked by Skeletal Muscle InterferencePacing and Clinical Electrophysiology, 1982
- Pacemaker Inhibition by Myopotentials Detected by Holter MonitoringPacing and Clinical Electrophysiology, 1982
- Myopotential Inhibition of Unipolar AV Sequential (DVI) PacemakerPacing and Clinical Electrophysiology, 1982
- Electromagnetic InterferencePacing and Clinical Electrophysiology, 1982
- The Effect of 60 Hertz Electric Fields and Currents on Implanted Cardiac PacemakersPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1978
- The Influence of Electromagnetic Environment on the Performance of Artificial Cardiac PacemakersThe Annals of Thoracic Surgery, 1968
- Environmental Influence on Implantable Cardiac PacemakersJAMA, 1964
- ELECTRICAL HAZARDS ASSOCIATED WITH CARDIAC PACEMAKING*Annals of the New York Academy of Sciences, 1964