The single-passage extraction of 18 F in rabbit bone
- 1 November 1986
- journal article
- research article
- Published by IOP Publishing in Clinical Physics and Physiological Measurement
- Vol. 7 (4) , 333-343
- https://doi.org/10.1088/0143-0815/7/4/003
Abstract
The only clinically applicable method for the quantitative measurement of blood flow to the skeleton which has so far been developed rests on the assumption that the initial extraction of the bone-seeking isotope 18F from blood by bone is known and constant. Previous work to measure the single-passage extraction ratio of this isotope in rabbit bone has been criticised, so a novel technique has been developed in which isotope recirculation cannot occur. In addition, the post mortem uptake of isotope from surrounding tissues and the vascular tracer content of the bone can be monitored. The apparent extraction ratios of two bone-seeking isotopes, 85Sr and 18F, were measured in nine animals, and extrapolated to the time of death from both the time at which dissection of the bones began (giving a maximum value) and the time at which it ended (giving a minimum). Mean blood flow to the femur was 0.562 ml min-1 (SD=0.170, n=15) and mean blood flow to the tibia was 0.290 ml min-1 (SD=0.140, n=12). Statistical analysis of the results showed that there were significant differences in the extrapolated ratio between animals and significantly higher extraction of isotope in the tibia than in the femur. There was no significant difference between the extraction of 85Sr and that of 18F. The best estimate of the single-passage extraction ratio of 85Sr and 18F which can be made, therefore, is that in rabbit femur it is 0.88 (SE 0.04) and in the rabbit tibia it is 1.08 (SE 0.04). Post mortem uptake of isotope increases the apparent extraction ratio by about 1% per minute.This publication has 17 references indexed in Scilit:
- Measurement of absolute bone blood flow by positron emission tomographySkeletal Radiology, 1986
- Reduction of skeletal blood flow in Paget's disease with disodium etidronate therapyBone, 1985
- Invalidity of single-passage measurements of the extraction of bone-seeking tracers in rats and rabbitsJournal of Orthopaedic Research, 1984
- Limitations of radioactive microspheres as tracers for bone blood flow and extraction ratio studiesCalcified Tissue International, 1980
- The short-term fixation of radiopharmaceuticals in boneEuropean Journal of Nuclear Medicine and Molecular Imaging, 1979
- The Single-Passage Extraction of 18F in Rabbit BoneClinical Science, 1974
- Some sources of error in measuring regional blood flow with radioactive microspheres.Journal of Applied Physiology, 1971
- Recommended Methods for Radioisotope Red‐Cell Survival Studies* A REPORT BY THE ICSH PANEL ON DIAGNOSTIC APPLICATIONS OF RADIOISOTOPES IN HAEMATOLOGYBritish Journal of Haematology, 1971
- Validity Studies of the Radioactive Microsphere Method for the Study of the Distribution of Cardiac Output, Organ Blood Flow, and Resistance in the Conscious Rhesus MonkeyCardiovascular Research, 1969
- Bone blood flow shown with F18 and the positron cameraAmerican Journal of Physiology-Legacy Content, 1965