Optimum tomographic reconstruction parameters for HMPAO brain SPET imaging: a practical approach based on subjective and objective indexes
- 1 July 1995
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 22 (7) , 671-677
- https://doi.org/10.1007/bf01254569
Abstract
The purpose of this study was to define an optimal strategy for the tomographic reconstruction procedure in routine brain single-photon emission tomography (SPET) studies, including the number of projections, filter function and matrix size. A set of projection data with different count densities was obtained from a technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) brain SPET acquisition from one volunteer. The projections were reconstructed with different filters and the quality of the reconstructed images was determined using both a subjective observer rating score and the Gilbert index. For each count density, the observers' choice corresponded to images with the lowest Gilbert index. The noise level in brain SPET sections was estimated and correlated with the fractal dimension. The results of this study indicate that although noise represents a fundamental component of brain SPET imaging, image quality also depends on the reconstructed spatial resolution. Image quality is satisfactorily described by fractal dimension. In addition the optimal filter function depends on the available count density. For high count levels, optimal reconstruction may be obtained by using a high-resolution matrix and a slightly smoother reconstruction filter. When count densities are low, best results are obtained by using a low-resolution matrix and a sharper filter. Finally, this study suggests that image quality is not influenced by the number of projections for equivalent count densities. These results were confirmed by 30 HMPAO brain SPET studies acquired in a routine clinical setting.Keywords
This publication has 19 references indexed in Scilit:
- An estimation of noise levels in HMPAO RCBF SPECT images using simulation and phantom data; comparison with results obtained from repeated normal controlsPhysics in Medicine & Biology, 1994
- Quantitative single-photon emission computed tomography: Basic and clinical considerationsSeminars in Nuclear Medicine, 1994
- SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theoryPhysics in Medicine & Biology, 1993
- Spatial resolution and count density requirements in brain SPECT imagingPhysics in Medicine & Biology, 1992
- Human visual perception and ROC methodology in medical imagingPhysics in Medicine & Biology, 1992
- A simple method for the measurement of local statistical noise levels in SPECTPhysics in Medicine & Biology, 1992
- Objective assessment of image quality: effects of quantum noise and object variabilityJournal of the Optical Society of America A, 1990
- Effect of resolution improvement on required count density in ECT imaging: a computer simulationPhysics in Medicine & Biology, 1985
- The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstructionPhysics in Medicine & Biology, 1977
- Iterative methods for the three-dimensional reconstruction of an object from projectionsJournal of Theoretical Biology, 1972