Imaging radiotracer model parameters in PET: a mixture analysis approach
- 1 January 1993
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 12 (3) , 399-412
- https://doi.org/10.1109/42.241867
Abstract
Two methodologies for fitting radiotracer models on a pixel-wise basis to PET data are considered. The first method does parameter optimization for each pixel considered as a separate region of interest. The second method also does pixel-wise analysis but incorporates an additive mixture representation to account for heterogeneity effects induced by instrumental and biological blurring. Several numerical and statistical techniques including cluster analysis, constrained nonlinear optimization, subsampling, and spatial filtering are used to implement the methods. A computer simulation experiment, modeling a standard F-18 deoxyglucose (FDG) imaging protocol using the UW-PET scanner, is conducted to evaluate the statistical performance of the parametric images obtained by the two methods. The results obtained by mixture analysis are found to have substantially improved mean square error performance characteristics. The total computation time for mixture analysis is on the order of 0.7 s/pixel on a 16 MIPS workstation. This results in a total computation time of about 1 h per slice for a typical FDG brain study.Keywords
This publication has 38 references indexed in Scilit:
- Smooth Mixture Estimation from Multichannel Image DataPublished by Springer Nature ,1992
- Imaging of hypoxia in human tumors with [F-18]fluoromisonidazoleInternational Journal of Radiation Oncology*Biology*Physics, 1992
- Michaelis-Menten Constraints Improved Cerebral Glucose Metabolism and Regional Lumped Constant Measurements with [18F]FluorodeoxyglucoseJournal of Cerebral Blood Flow & Metabolism, 1990
- Comparison of Data-Driven Bandwidth SelectorsJournal of the American Statistical Association, 1990
- Performance measurements of the SP3000/UW time-of-flight positron emission tomographIEEE Transactions on Nuclear Science, 1988
- Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data. GeneralizationsJournal of Cerebral Blood Flow & Metabolism, 1985
- A Preliminary Evaluation of the Use of the EM Algorithm for Estimating Parameters in Dynamic Tracer-StudiesIEEE Transactions on Nuclear Science, 1985
- Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake DataJournal of Cerebral Blood Flow & Metabolism, 1983
- Tomographic measurement of local cerebral glucose metabolic rate in humans with (F‐18)2‐fluoro‐2‐deoxy‐D‐glucose: Validation of methodAnnals of Neurology, 1979
- Statistical predictor identificationAnnals of the Institute of Statistical Mathematics, 1970