Determination of Known Exhalation Valve Damage Using a Negative Pressure User Seal Check Method on Full Facepiece Respirators
- 1 April 2003
- journal article
- research article
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 18 (4) , 237-243
- https://doi.org/10.1080/10473220301399
Abstract
A negative pressure user seal check (NPUSC) method was evaluated for its ability to adequately detect known exhalation valve leakage into a respirator. Three valves with different types of damage were included. Twenty-six test subjects, wearing full facepiece respirators, were asked to perform a NPUSC. Their responses as to whether they passed or failed the user seal check were compared to fit testing results from two quantitative fit test methods: ambient aerosol and controlled negative pressure. In addition, equipment developed at the University of Cincinnati was used to measure in-mask pressures that are generated during the performance of NPUSCs. This technique was employed to assess the ability of respirator wearers to properly conduct user seal checks. The data were analyzed to determine if the user seal check procedure is an effective method for detecting known exhalation valve damage. All test subjects reported passing the user seal check with the undamaged valve. With the warped valve installed, 95 percent of test subjects reported passing the user seal check. With the slit valve installed, 73 percent of test subjects reported passing. With the dirty valve installed, 65 percent reported passing. All fit factors, measured with the damaged valves, were below the Occupational Safety and Health Administration-recognized pass/fail criteria except one fit test with the respirator equipped with the slit valve. Results from the in-mask pressure measurements confirmed whether or not the subject properly conducted a user seal check, but did not detect respirator leakage. In conclusion, the performance of a NPUSC rarely helped to identify damaged exhalation valves. These results support the need for respirator inspection prior to donning with periodic fit testing and the performance of user seal checks as necessary components of an adequate respiratory protection program.Keywords
This publication has 7 references indexed in Scilit:
- Effectiveness of Fit Check Methods on Half Mask RespiratorsApplied Occupational and Environmental Hygiene, 1995
- Determinations of Known Respirator Leakage Using Controlled Negative Pressure and Ambient Aerosol QNFT SystemsAihaj Journal, 1995
- A Validation Study of Respirator Fit Testing by Controlled Negative PressureApplied Occupational and Environmental Hygiene, 1994
- Determination of Inspiratory Pressures and Flow Rates for Work Rate-Dependent Quantitative Respirator Fit TestingApplied Occupational and Environmental Hygiene, 1993
- A COMPARISON OF CONTROLLED NEGATIVE PRESSURE AND AEROSOL QUANTITATIVE RESPIRATOR FIT TEST SYSTEMS BY USING HUMAN SUBJECTSAihaj Journal, 1993
- Collection of Silica and Asbestos Aerosols by Respirators at Steady and Cyclic FlowAihaj Journal, 1990
- Performance of Respirator Expiratory ValvesAihaj Journal, 1967