CdZnTe strip detectors for astrophysical arc second imaging and spectroscopy: detector performance and radiation effects
- 18 October 1996
- proceedings article
- Published by SPIE-Intl Soc Optical Eng
- p. 616-628
- https://doi.org/10.1117/12.254023
Abstract
CdZnTe strip detectors have been fabricated and tested to show the ability for arc second imaging and spectroscopy. Two dimensional CdZnTe strip detectors with 100 micron pitch have been fabricated and wire bonded to readout electronics to demonstrate the ability to localize 22 to 122 keV photons to less than 100 microns. Good spectral resolution has also been achieved. The uniformity and relative efficiency of the strip detector are discussed. Radiation damage effects by intermediate energy neutrons and low energy protons on the surface and bulk performance of CdZnTe devices have been investigated and are presented. Activation and annealing of radiation effects have been seen and are discussed.Keywords