Kinematic accuracy of three surface registration methods in a three-dimensional wrist bone study.
- 2 April 2000
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 122 (5) , 528-533
- https://doi.org/10.1115/1.1289992
Abstract
The use of registration techniques to determine motion transformations noninvasively has become more widespread with the increased availability of the necessary software. In this study, three surface registration techniques were used to generate carpal bone kinematic results from a single cadaveric wrist specimen. Surface contours were extracted from specimen computed tomography volume images of the forearm, carpal, and metacarpal bones in four arbitrary positions. Kinematic results from each of three registration techniques were compared with results derived from multiple spherical markers fixed to the specimen. Kinematic accuracy was found to depend on the registration method and bone size and shape. In general, rotation errors of the capitate and scaphoid were less than 0.5 deg for all three techniques. Rotation errors for the other bones were generally less than 2 deg, although error for the trapezoid was greater than 2 deg in one technique. Translation errors of the bones were generally less than 1 mm, although errors of the trapezoid and trapezium were greater than 1 mm for two techniques. Tradeoffs existed in each registration method between image processing time and overall kinematic accuracy. Markerless bone registration (MBR) can provide accurate measurements of carpal kinematics and can be used to study the noninvasive, three-dimensional in vivo kinematics of the wrist and other skeletal joints.Keywords
This publication has 19 references indexed in Scilit:
- Noninvasive technique for measuring in vivo three‐dimensional carpal bone kinematicsJournal of Orthopaedic Research, 1999
- High-speed, three-dimensional kinematic analysis of the normal wristThe Journal of Hand Surgery, 1998
- Segmentation of carpal bones from 3D CT images using skeletally coupled deformable modelsPublished by Springer Nature ,1998
- Use of a Biocompatible Fiducial Marker in Evaluating the Accuracy of Computed Tomography Image RegistrationInvestigative Radiology, 1996
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Carpal bone kinematics and ligament lengthening studied for the full range of joint movementJournal of Biomechanics, 1993
- Roentgen stereophotogrammetryActa Orthopaedica, 1989
- Relative motion of selected carpal bones: A kinematic analysis of the normal wristThe Journal of Hand Surgery, 1988
- A least-squares algorithm for the equiform transformation from spatial marker co-ordinatesJournal of Biomechanics, 1988
- Kinematic behavior of the human wrist joint: A roentgen‐stereophotogrammetric analysisJournal of Orthopaedic Research, 1985