Experimental study of the influence of endoleak size on pressure in the aneurysm sac and the consequences of thrombosis
Open Access
- 1 January 2000
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 87 (1) , 71-78
- https://doi.org/10.1046/j.1365-2168.2000.01319.x
Abstract
Background: This was an experimental study of endovascular aortic surgery, looking at the relationship between the size of an endoleak, pressure in the aneurysm sac and the effect of thrombosis produced by coagulation. Methods: In three pigs, 16 saccular aneurysms were connected to the aorta by various side branches with different diameters and lengths (‘endoleaks’). Mean and pulse pressures were measured in the systemic circulation as well as in the aneurysm sac during the experiment. Duplex ultrasonography was used to determine whether the endoleak and the aneurysm were patent or thrombosed. Thrombosis was influenced by systemic tranexamic acid, fibrinogen in the aneurysm sac, Gelfoam in both endoleak and aneurysm sac, and by Histoacryl glue in the endoleak. Results: With an open endoleak, the mean pressure in the aneurysm and the aorta was identical. Mean aneurysm pressure was lower with a thrombosed endoleak and was related to the diameter of the endoleak. Pulse pressure was recorded in the aneurysm sac when there was an open endoleak and a non-thrombosed aneurysm, and was related to the diameter of the open endoleak. Thrombosed endoleaks never produced pulse pressure in the aneurysm. If Histoacryl and Gelfoam induced thrombosis of the endoleak, the decrease in mean aneurysm pressure was identical to that resulting from the spontaneous thrombosis of endoleaks. Conclusion: An open endoleak results in systemic arterial pressure in the aneurysm sac. Pulse pressure is detected if the aneurysm is patent, but absent if there is complete or partial thrombosis of the aneurysm. Endoleak thrombosis, either spontaneous or by embolization, is accompanied by a decrease in mean pressure and the absence of pulse pressure in the aneurysm sac. The extent to which these experimental findings are comparable to the clinical situation represents a field of further research.Keywords
This publication has 19 references indexed in Scilit:
- Stent attachment site–related endoleakage after stent graft treatment: An in vitro study of the effects of graft size, stent type, and atherosclerotic wall changesJournal of Vascular Surgery, 1999
- Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studiesBritish Journal of Surgery, 1999
- Endoleakage after stent-graft treatment of abdominal aneurysm: Implications on pressure and imaging—an in vitro studyJournal of Vascular Surgery, 1998
- Type I and Type II Endoleaks: A More Useful Classification for Reporting Results of Endoluminal AAA RepairJournal of Endovascular Surgery, 1998
- Endoleak after endovascular graft repair of experimental aortic aneurysms: Does coil embolization with angiographic “seal” lower intraaneurysmal pressure?Journal of Vascular Surgery, 1998
- Endoleaks after endovascular graft treatment of aortic aneurysms: Classification, risk factors, and outcomeJournal of Vascular Surgery, 1998
- Three-Year Experience With Modular Stent-Graft Devices for Endovascular AAA TreatmentJournal of Endovascular Surgery, 1997
- Fate of the excluded abdominal aortic aneurysm sac: Long-term follow-up of 831 patientsJournal of Vascular Surgery, 1996
- “Endoleak”—A Proposed New Terminology to Describe Incomplete Aneurysm Exclusion by an Endoluminal GraftJournal of Endovascular Surgery, 1996
- The effect of epsilon aminocaproic acid and tranexamic acid on thrombus size and strength in a simulated arterial aneurysmJournal of Neurosurgery, 1971