How should airways resistance be measured in young children: mask or mouthpiece?
- 1 June 2001
- journal article
- research article
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 17 (6) , 1244-1249
- https://doi.org/10.1183/09031936.01.00089501
Abstract
The reproducibility and acceptability of airways resistance measurements using the interrupter technique (MicroRint) obtained using a mouthpiece were compared with those using a face mask.Fifty children aged 4–7 yrs performed four sets of sixRintmeasurements; two using a mouthpiece and two using a face mask with integral mouthpiece.Complete data were obtained from 45 (90%) children using the mouthpiece and 43 (86%) children using the mask. The two methods were equally repeatable with comparable intraclass correlation coefficients (ICC) and coefficients of variation. MeanRintvalues obtained using the mouthpiece were significantly lower than those using the face mask ((mean±sd) mouthpiece=0.81±0.18 kPa·L−1·s, mask=0.88±0.24 kPa·L−1·s p=0.0002). Although the mean paired differences between the two methods were small (0.07 kPa·L−1·s), the ICC and limits of agreement confirmed that the two methods could not be used interchangeably. Sixty-seven per cent of children preferred the face mask but this was more time-consuming (p=0.03). Children did not produce more repeatable results using their preferred method, nor did they improve with practice.Repeatable airway resistance measurements using the interrupter technique can be obtained from young children using either a mouthpiece or a face mask, but there are significant clinical and statistical differences between the results obtained.Keywords
This publication has 21 references indexed in Scilit:
- Interrupter technique for evaluation of exercise-induced bronchospasm in childrenPediatric Pulmonology, 1999
- Oscillatory pressure transients after flow interruption during bronchial challenge test in childrenEuropean Respiratory Journal, 1997
- A portable device based on the interrupter technique to measure bronchodilator response in schoolchildrenEuropean Respiratory Journal, 1996
- Evaluation of the interrupter technique for measuring change in airway resistance in 5‐year‐old asthmatic childrenPediatric Pulmonology, 1995
- Lung function measurement in awake young childrenEuropean Respiratory Journal, 1995
- Evaluation of the interrupter technique for the use of assessing airway obstruction in childrenPediatric Pulmonology, 1994
- The accuracy of portable peak flow meters.Thorax, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Nasal resistance during infancyRespiration Physiology, 1978
- Peak Expiratory Flow Rates in Children Under 5 Years of AgeArchives of Disease in Childhood, 1970