Evaluation of the interrupter technique for measuring change in airway resistance in 5‐year‐old asthmatic children
- 1 December 1995
- journal article
- diagnostic and-therapeutic-method
- Published by Wiley in Pediatric Pulmonology
- Vol. 20 (6) , 387-395
- https://doi.org/10.1002/ppul.1950200609
Abstract
The interrupter technique is a noninvasive method for measuring airway resistance during quiet breathing which requires minimal subject cooperation. It, therefore, has enormous potential for use in young children unable to cooperate with conventional lung function tests. We evaluated the interrupter technique during bronchial challenge with methacholine administered by the tidal breathing method in 10 5‐year‐old asthmatic children. The mouth pressure/time [Pmo(t)] curve obtained following brief airflow interruption during the expiratory phase of quiet breathing was analyzed to determine the interrupter resistance R,int using four different methods: RintC, a smooth curve fit with back‐extrapolation; RintEO, calculated from the pressure change after the postinterruption oscillations had decayed (end‐oscillation); RintL two‐point linear fit with back‐extrapolation; and RintEL, calculated from the pressure change at the end of the period of interruption. The four Rint methods were compared for repeatability and sensitivity with the direct measurement of resistance by the forced oscillation technique (Rrs) and with an independent method of measuring the response to challenge, utilizing the change in transcutaneous oxygen tension (PtcO2). The sensitivity of the methods was defined by a sensitivity index (SI), the change after challenge expressed in multiples of the baseline standard deviation. The PtCo2 method had the lowest variability and was by far the most sensitive method (geometric mean SI 18.9), at least 1 doubling concentration more sensitive than the other techniques in every subject (P < 0.05). RintL was more sensitive than the other interrupter methods (geometric mean SI: RintL 4.2; RintC 1.O; RintEO 2.7; RintEL 3.1; P < 0.05) and similar in sensitivity to Rrs (geometric mean SI 4.6) in 7 out of 10 children in which this could be measured. We conclude that the interrupter method provides a simpler method than the oscillation technique for assessing airway obstruction in this age group. Pediatr Pulmonol. 1995; 20:387–395.Keywords
This publication has 33 references indexed in Scilit:
- The measurement of methacholine responsiveness in 5 year old children: three methods comparedEuropean Respiratory Journal, 1995
- Evaluation of the interrupter technique for the use of assessing airway obstruction in childrenPediatric Pulmonology, 1994
- Repeatability of methacholine challenge in asthmatic children measured by change in transcutaneous oxygen tension.Thorax, 1992
- Use of transcutaneous oxygen tension, arterial oxygen saturation, and respiratory resistance to assess the response to inhaled methacholine in asthmatic children and normal adults.Thorax, 1991
- Lung function and bronchial responsiveness measured by forced oscillometry after bronchopulmonary dysplasia.Archives of Disease in Childhood, 1988
- Computer analysis of physical factors affecting the use of the interrupter technique in infantsPediatric Pulmonology, 1988
- Lung function and bronchial responsiveness in children who had infantile bronchiolitisPediatric Pulmonology, 1987
- Histamine‐induced asthma in children: effects on the ventilation‐perfusion relationshipClinical Physiology and Functional Imaging, 1985
- Effect of the cheeks and the compliance of alveolar gas on the measurement of respiratory variablesRespiration Physiology, 1982
- ESTIMATION OF PULMONARY RESISTANCE BY REPETITIVE INTERRUPTION OF AIRFLOWJournal of Clinical Investigation, 1959