Computer analysis of physical factors affecting the use of the interrupter technique in infants
- 1 January 1988
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 4 (4) , 219-224
- https://doi.org/10.1002/ppul.1950040406
Abstract
The interrupter technique involves measuring pressure changes at the airway opening following abrupt interruption of airflow, and relies on rapid equilibration of alveolar and airway opening pressures. Following airway occlusion one generally sees a rapid change in airway opening pressure, Pinit, which reflects the resistive pressure drop across the system, followed by a secondary, slower pressure change, Pdif, which reflects the tissue visco‐elastic properties together with any redistribution of gases occurring between lung units at different pressure at the time of interruption. Physical factors in the measuring equipment, i.e., the time taken for valve closure and the presence of a proximal compliant compartment, can cause errors in the calculation of resistance and elastance using the interrupter technique. A computer model was used to determine the effects of these factors on the calculation of resistance and elastance in normal infants, premature infants, and infants with bronchopulmonary dysplasia. The elastance from 25 ml of dead space gas did not introduce significant errors into the measurements in any group of infants, but the presence of an unsupported upper airway caused errors of up to 245%. Increasing valve closure time introduced progressively larger errors into the calculation of resistance and elastance. To keep these errors acceptably small, an occlusion valve should close in 20 ms or less.Keywords
This publication has 12 references indexed in Scilit:
- Effect of lung volume on interrupter resistance in cats challenged with methacholineJournal of Applied Physiology, 1988
- Effect of valve closure time on the determination of respiratory resistance by flow interruptionMedical & Biological Engineering & Computing, 1987
- Analysis of the behavior of the respiratory system with constant inspiratory flowJournal of Applied Physiology, 1985
- Mechanical properties of the upper airwayJournal of Applied Physiology, 1983
- Lung Volume and Lung Mechanics in Infancy Lateral or Supine Posture?Pediatric Research, 1982
- Effect of the cheeks and the compliance of alveolar gas on the measurement of respiratory variablesRespiration Physiology, 1982
- A reevaluation of the interrupter technique for airway resistance measurement.Journal of Applied Physiology, 1974
- The viscous resistance of the lung tissues in newborn infantsThe Journal of Pediatrics, 1966
- Evaluation of Airway Interruption Technique as a Method for Measuring Pulmonary Air-Flow ResistanceJournal of Applied Physiology, 1954