Total Condylar Knee Replacement
Top Cited Papers
- 1 July 2001
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 388, 10-17
- https://doi.org/10.1097/00003086-200107000-00004
Abstract
Between 1976 and 1979, 220 total knee replacements were done on 164 patients using the Total Condylar Knee replacement. The diagnosis was rheumatoid arthritis in 111 knees and osteoarthritis in 109 knees. Patients with 157 knees are known to have died as of December 1998, leaving 63 knees in patients who are still alive. Twelve patients with 18 knees were lost to followup. The average 20-year followup data (range, 18–22 years) are presented for 45 knees in 30 patients using Knee Society evaluations. The average Knee Society clinical score for the surviving patients was 88 points, and the average functional score was 58 points. The radiographic followup averaged 19 years. The average overall alignment was 3° valgus. Femoral lucencies were present in 17 of 40 adequate lateral views, most commonly about the anterior and posterior surfaces. Two femoral components were loose. Twenty-two tibial components had radiolucencies; four radiolucencies were circumferential. The remaining 41 knees retained a well-fixed cemented central peg despite proximal interface lucencies. From the group of 220 knees, 14 revisions have been done at an average of 11.4 years postoperative. Two knee replacements were revised for isolated tibial loosening, whereas one knee replacement had isolated femoral loosening. Three knee replacements were revised for loosening of both components, and one was revised for isolated patellar loosening. Four patients had sepsis develop; three of these four patients were treated with two-stage revision, and one underwent fusion. Three patients were treated for supracondylar fractures. The Total Condylar Knee replacement maintains excellent durability at 20-years followup.This publication has 15 references indexed in Scilit:
- Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1999
- Modular Tibial Insert MicromotionPublished by Wolters Kluwer Health ,1998
- Tibial Insert Undersurface as a Contributing Source of Polyethylene Wear DebrisClinical Orthopaedics and Related Research, 1997
- Survivorship of Cemented Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1997
- The Press-Fit Condylar Modular Total Knee System. Four-to-Six-Year Results with a Posterior-Cruciate-Substituting Design*Journal of Bone and Joint Surgery, 1997
- Long-term results of total knee arthroplasty in class 3 and 4 rheumatoid arthritisThe Journal of Arthroplasty, 1996
- Osteolysis of the distal femur after total knee arthroplastyThe Journal of Arthroplasty, 1994
- Comparison of metal-backed and all-polyethylene tibial components in cruciate condylar total knee arthroplastyThe Journal of Arthroplasty, 1993
- The posterior stabilized condylar prosthesisJournal of Bone and Joint Surgery, 1982
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958