Ion sampling effects under conditions of total solvent consumption
- 20 April 2006
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (10) , 1538-1544
- https://doi.org/10.1002/rcm.2511
Abstract
The motivation of this work was to study some of the properties of nanoelectrospray operation under conditions where the entire sprayed liquid is vaporized and inhaled into the vacuum system. Under these conditions the desolvation requirements, sampling efficiency, concentration versus mass sensitivity, and molar response characteristics of various compounds were studied. The combined efficiency of ion production from solution and transfer into the vacuum system, referred to as sampling efficiency, is presented under various inlet conditions including different flow rates, solution compositions, and compound types. Under ideal solvent conditions the results for favorable compounds show sampling efficiencies of 70–85% at flows in the range of 50–500 nL/min. Efficiencies were lower for aqueous samples and compounds of different structures gave different molar response factors under these high sampling efficiency conditions. The relative molar response factors are presented in terms of those observed with higher flow rate sources which operate at significantly lower sampling efficiencies. In all cases, operating in this flow regime, the ion count rate was directly proportional to the absolute mass of analyte molecules entering the source. The experimental source used to carry out these studies included gas nebulization to stabilize the electrospray process, a heated laminar flow chamber to enhance desolvation and ion production, and various atmosphere-to-vacuum aperture diameters to maximize ion transfer. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 15 references indexed in Scilit:
- Analysis of oxysterols by electrospray tandem mass spectrometryJournal of the American Society for Mass Spectrometry, 2006
- Ultra‐low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: standard‐free quantitative estimation of metabolite levels in drug discoveryRapid Communications in Mass Spectrometry, 2006
- Efficiency of nano-electrospray ionizationJournal of the American Society for Mass Spectrometry, 2005
- Stable gradient nanoflow LC-MSJournal of the American Society for Mass Spectrometry, 2005
- Automated orthogonal control system for electrospray ionizationJournal of the American Society for Mass Spectrometry, 2004
- Particle discriminator interface for nanoflow ESI-MSJournal of the American Society for Mass Spectrometry, 2003
- Analytical Properties of the Nanoelectrospray Ion SourceAnalytical Chemistry, 1996
- Improved Collisionally Activated Dissociation Efficiency and Mass Resolution on a Triple Quadrupole Mass Spectrometer SystemAnalytical Chemistry, 1995
- Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteinsJournal of the American Society for Mass Spectrometry, 1994
- Ion spray mass spectrometric detection for liquid chromatography: A concentration- or a mass-flow-sensitive device?Journal of Chromatography A, 1993