Digital geometric measurements in comparison to cinefilm analysis of coronary artery dimensions
- 1 April 1993
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 28 (4) , 283-290
- https://doi.org/10.1002/ccd.1810280404
Abstract
Six months follow‐up post‐PTCA angiograms from 31 patients were acquired digitally and on cinefilm and used for a comparison of geometric coronary measurements at the site of the previous dilatation. On 70 images of 34 coronary segments quantitative analysis was performed both on‐line, using the Automated Coronary Analysis package of the Philips Digital Cardiac Imaging System (DCI, pixel matrix 512 × 512) and off‐line, using the Cardiovascular Angiography Analysis System (CAAS). With the CAAS a cine‐video conversion is performed and a 6.9 × 6.9 mm region of interest from the 18 × 24 mm cineframe is digitized into a 512 × 512 pixel matrix. In both systems the vascular contours are assessed by means of operator‐independent edge detection algorithms. The angiographic catheter was used for calibration.Best agreement between DCI and CAAS was found for obstruction diameter and minimal luminal diameter, respectively (r = 0.82; y = 0.12 + 0.97x; SEE = 0.29). The reconstructed reference diameter related to a computed reference contour yields lower correlation (r = 0.76; y = 0.27 + 0.91x; SEE = 0.37). Worst results were obtained from the relative measure of percent diameter stenosis as well as from the derived parameter of plaque area.The on‐line digital approach of geometric coronary assessments provides good agreement with cinefilm analysis when direct measurements of coronary dimensions are applied.Keywords
This publication has 27 references indexed in Scilit:
- A new approach for the automated definition of path lines in digitized coronary angiogramsThe International Journal of Cardiovascular Imaging, 1990
- Restenosis after coronary angioplasty: New standards for clinical studiesJournal of the American College of Cardiology, 1990
- Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: Failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilationJournal of the American College of Cardiology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The radiographic assessment of coronary blood flow parameters.Circulation, 1985
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and results of exercise thallium scintigraphy.Circulation, 1985
- Assessment of dimensions and image quality of coronary contrast catheters from cineangiogramsCatheterization and Cardiovascular Diagnosis, 1985
- Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: Diameter versus densitometric area measurementsThe American Journal of Cardiology, 1984
- Coronary angiographic examination with the dynamic spatial reconstructor.Circulation, 1984