On the degeneracy of the IMRT optimization problem
- 25 October 2002
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 29 (11) , 2584-2589
- https://doi.org/10.1118/1.1500402
Abstract
One approach to the computation of photonIMRT treatment plans is the formulation of an optimization problem with an objective function that derives from an objective density. An investigation of the second-order properties of such an objective function in a neighborhood of the minimizer opens an intuitive access to many traits of this approach. A general finding is that only a small subset of the parameter space has nonzero curvature, while the objective function is entirely flat in a neighborhood of the minimizer in most directions. The dimension of the subspace of vanishing curvature serves as a measure for the degeneracy of the solution. This finding is important both for algorithm design and evaluation of the mathematical model of clinical intuition, expressed by the objective function. The structure of the subspace of great curvature is found to be imposed on the problem by conflicts between objectives of target and critical structures. These conflicts and their corresponding modes of resolution form a common trait between all reasonable treatment plans of a given case. The high degree of degeneracy makes the use of a conjugate gradient optimization algorithm particularly favorable since the number of iterations to convergence is equivalent to the number of different eigenvalues of the curvature tensor and is hence independent from the number of optimization parameters. A high level of degeneracy of the fluence profiles implies that it should be possible to stipulate further delivery-related conditions without causing severe deterioration of the dose distribution.Keywords
This publication has 12 references indexed in Scilit:
- Leaf position optimization for step-and-shoot IMRTInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC deliveryPhysics in Medicine & Biology, 2001
- Smoothing intensity-modulated beam profiles to improve the efficiency of deliveryMedical Physics, 2001
- The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapyMedical Physics, 2000
- Intensity modulated photon beams subject to a minimal surface smoothing constraintPhysics in Medicine & Biology, 2000
- Hyperion — An integrated IMRT planning toolPublished by Springer Nature ,2000
- Numerical OptimizationPublished by Springer Nature ,1999
- An objective function for radiation treatment optimization based on local biological measuresPhysics in Medicine & Biology, 1999
- Inverse planning with constraints to generate smoothed intensity-modulated beamsPhysics in Medicine & Biology, 1998
- Multiple local minima in radiotherapy optimization problems with dose–volume constraintsMedical Physics, 1997