High performance micro-channel air cooling
- 4 December 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Abstract
A high performance, compact air-cooling technology is discussed. It combines the microlaminar flow concept with an efficient heat sink design in order to achieve a cooling performance comparable to that of complex water-cooled modules. The thermal resistance of the microlaminar heat sinks was measured to be less than 2 degrees C/W of power dissipated in a 1-cm/sup 2/ chip at an air flow rate of 2 ft/sup 3//min. The required air pressure depends on the desired volumetric efficiency. The capability to remove in excess of 600 W from a multichip module (25 chips at 25 W and 16% chip-to-substrate coverage) with a quiet 10-W tubeaxial fan has been demonstrated. The volume of the complete module, including the plenum and the fan, is only about 1 liter. The chips are held to a maximum temperature rise of 55 degrees C above ambient. Even higher cooling performance at greater chip-to-substrate coverage was shown to be possible with larger air movers.Keywords
This publication has 6 references indexed in Scilit:
- High performance micro-channel air coolingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Thermal Management of Air- and Liquid-Cooled Multichip ModulesIEEE Transactions on Components, Hybrids, and Manufacturing Technology, 1987
- Thermal management in semiconductor device packagingProceedings of the IEEE, 1985
- Narrow Channel Forced Air Heat SinkIEEE Transactions on Components, Hybrids, and Manufacturing Technology, 1984
- A Conduction-Cooled Module for High-Performance LSI DevicesIBM Journal of Research and Development, 1982