Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique
- 5 April 2000
- journal article
- Published by Wiley in Medical Physics
- Vol. 27 (4) , 737-744
- https://doi.org/10.1118/1.598936
Abstract
Dose per monitor unit in photon fields generated by clinical linear accelerators can be affected by the backscattered radiation into the monitor chamber from collimator jaws. Thus, it is necessary to account for the backscattered radiation in computing monitor unit setting for a treatment field. In this work, we investigated effects of the backscatter from collimator jaws based on Monte Carlo simulations of a clinical linear accelerator. The backscattered radiation scored within the monitor chamber was identified as originating either from the upper jaws (Y jaws), or from the lower jaws (X jaws). From the results of Monte Carlo simulations, ratios of the monitor-chamber-scored dose caused by the backscatter to the dose caused by the forward radiation, R(x,y), were modeled as functions of the individual X and Y jaw positions. The amount of the backscattered radiation for any field setting was then computed as a compound contribution from both the X and Y jaws. The dose ratios of R(x,y) were then used to calculate the change in photon output caused by the backscatter, Scb(x,y). Results of these calculations were compared with available measured data based on counting the electron pulses or charge from the electron target of an accelerator. Data from this study showed that the backscattered radiation contributes approximately 3% to the monitor-chamber-scored dose. A majority of the backscattered radiation comes from the upper jaws, which are located closer to the monitor chamber. The amount of the backscatter decreases approximately in a linear fashion with the jaw opening. This results in about a 2% increase of photon output from a 10 cm x 10 cm field to a 40 cm x 40 cm field. The off-axis location of the jaw opening does not have a significant effect on the magnitude of the backscatter. The backscatter effect is significant for monitor chambers using kapton windows, particularly for treatment fields using moving jaws. Applying the backscatter correction improves the accuracy of monitor-unit calculation using a model-based dose calculation algorithm such as the convolution method.Keywords
This publication has 16 references indexed in Scilit:
- Measurement of backscatter to the monitor chamber of medical accelerators using target chargeMedical Physics, 1998
- A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x‐ray beamsMedical Physics, 1997
- Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam modelMedical Physics, 1997
- Accurate characterization of Monte Carlo calculated electron beams for radiotherapyMedical Physics, 1997
- Flattening-filter-based empirical methods to parametrize the head scatter factorMedical Physics, 1996
- BEAM: A Monte Carlo code to simulate radiotherapy treatment unitsMedical Physics, 1995
- A Monte Carlo study of accelerator head scatterMedical Physics, 1994
- Backscatter into the beam monitor chamber: Implications for dosimetry of asymmetric collimatorsMedical Physics, 1993
- Telescopic measurements of backscattered radiation from secondary collimator jaws to a beam monitor chamber using a pair of slitsMedical Physics, 1989