Evaluation of Blood Pressure Measuring Devices
- 1 January 1993
- journal article
- review article
- Published by Taylor & Francis in Clinical and Experimental Hypertension
- Vol. 15 (6) , 1087-1097
- https://doi.org/10.3109/10641969309037096
Abstract
Validation of blood pressure measuring devices is a relatively new field of research. There are two national protocols for validating blood pressure measuring devices: the protocol of the American Association for the Advancement of Medical Instrumentation (AAMI) and the protocol of the British Hypertension Society (BHS), each of which has recently been revised. 19 blood pressure measuring devices have been validated according to one or both of these protocols. These protocols have been beneficial in drawing attention to the potential inaccuracy of blood pressure measuring systems, they permit comparison between devices and they have brought manufacturers of blood pressure measuring devices into closer contact with the profession. There are some inherent weaknesses in both protocols which include the fallibility of the 'gold standard', the lack of provision for validation in special circumstances and in special groups, such as the elderly and pregnant women, and failure to allow for deteriorating accuracy with higher pressure levels. The revised BHS protocol attempts to redress these deficiencies.Keywords
This publication has 18 references indexed in Scilit:
- How ??scientific?? is blood pressure measurement in leading medical journals?Journal Of Hypertension, 1990
- The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systemsJournal Of Hypertension, 1990
- Inaccuracy of seven popular sphygmomanometers for home measurement of blood pressureJournal Of Hypertension, 1990
- 1989 Guidelines for the management of mild hypertension: memorandum from a WHO/ISH MeetingJournal Of Hypertension, 1989
- Body weight, sodium intake and blood pressureJournal Of Hypertension, 1989
- Validation of portable noninvasive blood pressure monitoring devices: Comparisons with intra-arterial and sphygmomanometer measurementsAmerican Heart Journal, 1988
- Standardized Methods for Comparison of SphygmomanometersJournal Of Hypertension, 1984
- Concurrent validity studies of blood pressure instrumentation. The Philadelphia Blood Pressure Project.Hypertension, 1984
- Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.BMJ, 1978
- Evaluation of performance of selected devices for measuring blood pressureThe American Journal of Cardiology, 1973