Polymer membrane‐based polyion sensors: Development, response mechanism, and bioanalytical applications
- 1 September 1995
- journal article
- review article
- Published by Wiley in Electroanalysis
- Vol. 7 (9) , 823-829
- https://doi.org/10.1002/elan.1140070907
Abstract
Polymer membrane type ion‐selective electrodes (ISEs) are now used routinely to measure clinically important ions (e.g., Na+, K+, Ca2+) in undiluted blood. However, efforts to develop similar sensors suitable for the direct detection of larger biomolecules have been less successful owing to the difficulty in identifying appropriate membrane chemistries that yield a significant and selective response toward the desired macromolecular analytes. Recently, we have found that poorly plasticized polymer membranes (PVC) doped with lipophilic anion and cation exchangers exhibit unexpectedly large and reproducible potentiometric responses to low levels (< 1 μM) of certain biomedically important macromolecular polyionic species (heparin and protamine). This article provides data demonstrating how the specific membrane formulation and electrode geometry used influence the magnitude of the polyion EMF responses observed. The results suggest a non‐ equilibrium/steady‐state polyion extraction process is responsible for the potentiometric heparin and protamine responses exhibited by appropriately formulated membranes. The practical utility of these sensors for monitoring heparin levels in blood as well as heparin/ protamine binding to other biologically important macromolecules will be described. Further, the prospects of adapting the same polyion extraction chemistry to devise optically sensitive thin polymer films for monitoring heparin will also be addressed.Keywords
This publication has 12 references indexed in Scilit:
- Optical Detection of Macromolecular Heparin via Selective Coextraction into Thin Polymeric FilmsAnalytical Chemistry, 1995
- Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical ApplicationsAnalytical Biochemistry, 1995
- Response Mechanism of Polymer Membrane-Based Potentiometric Polyion SensorsAnalytical Chemistry, 1994
- Direct potentiometric membrane electrode measurements of heparin binding to macromoleculesElectroanalysis, 1993
- Design, manufacture and characterization of an optical fiber glucose affinity sensor based on an homogeneous fluorescence energy transfer assay systemAnalytica Chimica Acta, 1993
- Electrochemical sensor for heparin: further characterization and bioanalytical applicationsAnalytical Chemistry, 1993
- Theoretical aspects of bulk optode membranesAnalytica Chimica Acta, 1992
- Heparin binding to human plasma low-density lipoproteins: dependence on heparin sulfation degree and chain lengthBiochemistry, 1992
- Heparin-responsive electrochemical sensor: a preliminary studyAnalytical Chemistry, 1992
- Interpretation of the selectivity and detection limit of liquid ion-exchanger electrodesTalanta, 1988