Performance of Human Mass Balance/Metabolite Identification Studies Using Stable Isotope (13C, 15N) Labeling and Continuous‐Flow Isotope‐Ratio Mass Spectrometry as an Alternative to Radioactive Labeling Methods
- 8 March 1993
- journal article
- research article
- Published by Wiley in The Journal of Clinical Pharmacology
- Vol. 33 (3) , 246-252
- https://doi.org/10.1002/j.1552-4604.1993.tb03951.x
Abstract
Stable isotope labeling in therapeutic and subtherapeutic quantities of drug (15N213C‐phenobarbital) can be quantitated in biological matrices (urine) and high performance liquid chromatography (HPLC) peaks from urine using continuous‐flow isotope‐ratio mass spectrometry (CF‐IRMS). Standard curves for 15N213C‐phenobarbital were reproducible and linear (R2 > 0.985) over the ranges of 3–100 μg/mL for whole urine (1SN2 or 13C labeling) and 0.1–8.0 μg/mL for HPLC peaks derived from urine (15N2 labeling). The lower limit of quantitation values for urine drug concentration was 0.46–2.62 μg/mL in whole urine and 0.10–0.70 μg/mL in HPLC peaks. Validation samples quantitated with these standard curves yielded close to expected values. These data suggest stable isotope labeling and CF‐IRMS may be used as an alternative to 14C labeling and radioactivity counting methods in mass balance/metabolite identification and other biomedical studies.Keywords
This publication has 10 references indexed in Scilit:
- Mass spectrometryAnalytical Chemistry, 1992
- Comparison of two elemental-analyzer gas-isotope-ratio mass spectrometer systems in the simultaneous measurement of carbon-13/carbon-12 ratios and carbon content in organic samplesAnalytical Chemistry, 1992
- Automated analysis system for coupled .delta.13C and .delta.15N measurementsAnalytical Chemistry, 1992
- On-line measurements of 13C enrichments in rat breath: Non-invasive method for in vivo study of drug enzymatic inductionJournal of Chromatography B: Biomedical Sciences and Applications, 1991
- Simultaneous determination of p-hydroxylated and dihydrodiol metabolites of phenytoin in urine by high-performance liquid chromatographyJournal of Chromatography A, 1990
- Simultaneous separation and determination (in serum) of phenytoin and carbamazepine and their deuterated analogues by high-performance liquid chromatography—ultraviolet detection for tracer studiesJournal of Chromatography A, 1990
- Rapid sample throughput for biomedical stable isotope tracer studiesJournal of Mass Spectrometry, 1988
- Evaluation of isotope ratio (IR) mass spectrometry for the study of drug metabolismJournal of Mass Spectrometry, 1985
- Gas chromatography—stable isotope ratio analysis at natural abundance levelsJournal of Mass Spectrometry, 1984
- The Excretion of Isotope in Urea and Ammonia for Estimating Protein Turnover in Man with [15N]GlycineClinical Science, 1981