Dynamic Delay and Maximal Dynamic Error in Continuous Biosensors
- 1 January 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (8) , 1292-1297
- https://doi.org/10.1021/ac960030d
Abstract
When biosensors are operated continuously, a dynamic delay and a dynamic error relate the sensor signal to the changing analyte concentration. The dynamic delay is the temporal displacement of the signal, or the lag, and is specified solely by properties of the biosensor and external mass transfer. The dynamic error is the difference between the actual concentration and the simultaneous reported concentration and is the product of the dynamic delay and the instantaneous rate of concentration change. In real-time operation of sensors, a maximal dynamic error based on the maximal expected rate of concentration change must be employed to estimate the worst-case error because the actual instantaneous rate is not independently known. Values of dynamic delay and maximal dynamic error that are acceptable in particular monitoring situations can be used in the design of acceptable continuous biosensors. This analysis suggests experimental alternatives to the standard response time approach for sensor characterization that are particularly advantageous for continuously operated biosensors. The concepts are applied here to in vitro operation of a continuous glucose sensor.Keywords
This publication has 17 references indexed in Scilit:
- Comments on Time Lags and Dynamic Delays in Diffusion/Reaction SystemsThe Journal of Physical Chemistry, 1995
- Dynamic concentration challenges for biosensor characterizationBiosensors and Bioelectronics, 1993
- Algebraic, differential, and integral relations for membranes in series and other multilaminar media: permeabilities, solute consumption, lag times, and mean first passage timesThe Journal of Physical Chemistry, 1991
- Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensorsJournal of Biomedical Engineering, 1989
- A protocol for the routine measurement of lactate and pyruvate in cord bloodBJOG: An International Journal of Obstetrics and Gynaecology, 1989
- Transient response of the two-dimensional glucose sensorAnalytical Chemistry, 1988
- A telemetry-instrumentation system for chronically implanted glucose and oxygen sensorsIEEE Transactions on Biomedical Engineering, 1988
- Biosensors: fundamentals and applicationsAnalytica Chimica Acta, 1987
- A novel rotated disc electrode and time lag method for characterizing mass transport in liquid‐membrane systemsAIChE Journal, 1980
- Penetrant time lag in a diffusion-reaction system. CommentsThe Journal of Physical Chemistry, 1980