The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
- 1 November 1993
- journal article
- other
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 21 (6) , 880-886
- https://doi.org/10.1177/036354659302100622
Abstract
Twenty-seven paired human cadaveric knee specimens were used to determine the effect of surgical technique and various interference screw parameters on the pullout strength of patellar tendon femoral bone blocks. The study compared the fixation strength of endoscop ically inserted and conventional "rear-entry" screws of different diameters and lengths. In all tests the most frequent mode of failure was bone block pullout from the interference screw. There was no significant differ ence in fixation strength between 9-mm diameter screws inserted through a conventional rear-entry tech nique and 7-mm diameter screws inserted through an endoscopic technique. There was no significant effect of screw length on fixation strength. The pullout force for 20-mm long screws increased on average 120% when 7-mm diameter screws were compared with 5.5- mm diameter screws. There was no significant effect of increased screw core diameter on fixation strength. There was a weak positive correlation ( r2 = 0.45) between screw insertion torque and pullout force. Our measured mean pullout force for the 7-mm endoscopi cally inserted screws of 362 ± 198 N represents 20.1 % of the failure load of the normal young adult anterior cruciate ligament. Our data indicate that properly in serted 7-mm diameter endoscopic interference screws can provide fixation strengths of patellar tendon ante rior cruciate ligament grafts equivalent to those of con ventional 9-mm diameter rear-entry, outside-in screws.Keywords
This publication has 23 references indexed in Scilit:
- Anterior cruciate ligament replacements: A mechanical study of femoral attachment location, flexion angle at tensioning, and initial tensionJournal of Orthopaedic Research, 1990
- Factors affecting the region of most isometric femoral attachmentsThe American Journal of Sports Medicine, 1989
- Biomechanics of fascia lata ligament replacements: Early postoperative changes in the goatJournal of Orthopaedic Research, 1988
- Ligament length relationships in the moving kneeJournal of Orthopaedic Research, 1988
- An in vitro study of anterior cruciate ligament graft placement and isometryThe American Journal of Sports Medicine, 1988
- Arthroscopic anterior cruciate ligament reconstruction with patellar tendonTechniques in Orthopaedics, 1988
- The relationship of the femoral attachment site to the isometric tracking of the anterior cruciate ligament graftThe American Journal of Sports Medicine, 1987
- A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1987
- Early knee motion after open and arthroscopic anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1987
- Vascularized Patellar Tendon Graft with Rigid Internal Fixation for Anterior Cruciate Ligament InsufficiencyClinical Orthopaedics and Related Research, 1983