Nonanatomic placement of the posterior horn may occur during arthroscopic implantation of a meniscal transplant. The objective of this study was to determine whether nonantomic placement adversely affects the contact pressure distribution on the medial tibial plateau. Medial meniscal autografts were placed in eight cadaveric knees with the posterior horn tunnel in nonanatomic locations (5 mm medial and 5 mm posterior) and in the anatomic location. The contact pressure distribution of the medial articular surface of the tibia was measured with pressure-sensitive film under a 1200-N compressive load at 0°, 15°, 30°, and 45° of flexion. The maximum pressure, mean pressure, contact area, and anterior/posterior and medial/lateral locations of the centroid of contact area were compared. Placement of the posterior horn tunnel in the nonanatomic medial location caused a significant increase in the normalized maximum pressure over all flexion angles, an increase in the normalized mean pressure at 45°, and a posterior shift in the centroid of contact area over all flexion angles. Placement in the nonanatomic posterior location caused a significant posterior shift in the centroid of contact area over all flexion angles. Surgeons should place the posterior horn tunnel of a medial meniscal transplant within a tolerance tighter than 5 mm medial and 5 mm posterior to the anatomic location because nonanatomic placement significantly alters the contact pressure distribution.Keywords
This publication has 16 references indexed in Scilit:
- A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial jointsJournal of Biomechanics, 1998
- An In Vitro Osteotomy Method to Expose the Medial Compartment of the Human KneeJournal of Biomechanical Engineering, 1997
- The Effect of Allograft Meniscal Replacement on Intraarticular Contact Area and Pressures in the Human KneeThe American Journal of Sports Medicine, 1997
- A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee JointJournal of Biomechanical Engineering, 1995
- The spatial and pressure resolution of fuji pressure-sensitive filmExperimental Mechanics, 1995
- Implementation of a Five Degree of Freedom Automated System to Determine Knee Flexibility In VitroJournal of Biomechanical Engineering, 1990
- Material Properties and Structure-Function Relationships in the MenisciClinical Orthopaedics and Related Research, 1990
- Quantitative assessment of gait determinants during single stance via a three-dimensional model—Part 1. Normal gaitJournal of Biomechanics, 1989
- Tensile properties of human knee joint cartilage. II. Correlations between weight bearing and tissue pathology and the kinetics of swellingJournal of Orthopaedic Research, 1987
- In-Vitro of Measurement of Static Pressure Distribution in Synovial Joints—Part I: Tibial Surface of the KneeJournal of Biomechanical Engineering, 1983