Electron Gun Using a Field Emission Source
- 1 April 1968
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 39 (4) , 576-583
- https://doi.org/10.1063/1.1683435
Abstract
A new electron gun has been built which features mechanical and optical simplicity. Theoretically, it can produce a focused spot having a radius smaller than 50 Å and provide 1000 times more intensity than a hot filament system having a similar final spot size. The increase in intensity is made possible by using a field emission electron source operating at a pressure of 10−9 Torr, which is provided (without baking) using commercially available pumps. The small spot is produced by using two properly shaped electrodes which accelerate and focus the electrons from the tip. It would take a hot filament gun and at least two additional lenses to replace this field emission gun when a spot radius less than 100 Å is required. Even then the brightness of the conventional source would be too low to make use of the small spot size obtained. The optical properties for the new gun were predicted on a computer and experimentally confirmed in a new scanning electron microscope. The aperture aberration coefficient was measured to be no more than a factor of two greater than the theoretical value of 1.5 cm. A spot radius of 250 Å has been measured, and this value is to be compared with the theoretical value of 150 Å. Although it was convenient to measure the spot directly only at a relatively large image distance (11.3 cm), calculations imply that the gun can provide a spot radius less than 25 Å when very small image distances are used. The gun can be used in pulsed operation because all optical properties are constant for a given voltage ratio so that application of the electrode voltages by means of a voltage divider provides automatic focusing for arbitrary changes in the applied voltage. The methods used to make and operate reliable high field emission tips are reviewed, and a technique is described for changing the required tip voltage to obtain a given emission current.Keywords
This publication has 14 references indexed in Scilit:
- Experiments with Quadrupole Lenses in a Scanning MicroscopeJournal of Applied Physics, 1967
- Scanning Electron Microscopes: Is High Resolution Possible?Science, 1966
- Scanning Electron MicroscopyPublished by Elsevier ,1966
- Display System for Use with a Scanning Electron Energy Analyzing MicroscopeIEEE Transactions on Nuclear Science, 1965
- A Simple Method for Deriving, from Measured I(V) Data, Information on the Geometry of a Field Emission Current Source of Unknown CharacteristicsJournal of Applied Physics, 1962
- Stable, High Density Field Emission Cold CathodeJournal of Applied Physics, 1960
- The Field Emitter: Fabrication, Electron Microscopy, and Electric Field CalculationsJournal of Applied Physics, 1953
- Field Emission: Large Current Densities, Space Charge, and the Vacuum ArcPhysical Review B, 1953
- The effect of the image force on the emission and reflexion of electrons by metalsProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1928
- Electron emission in intense electric fieldsProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1928