Estimation of Functional Residual Capacity at the Bedside Using Standard Monitoring Equipment: A Modified Nitrogen Washout/Washin Technique Requiring a Small Change of the Inspired Oxygen Fraction
- 1 July 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 101 (1) , 206-212
- https://doi.org/10.1213/01.ane.0000165823.90368.55
Abstract
We developed a modified nitrogen washin/washout technique based on standard monitors using inspiratory and end-tidal gas concentration values for functional residual capacity (FRC) measurements in patients with acute respiratory failure (ARF). For validation we used an oxygen-consuming lung model ventilated with an inspiratory oxygen fraction (Fio(2)) between 0.3 and 1.0. The respiratory quotient of the lung model was varied between 0.7 and 1.0. Measurements were performed changing Fio(2) with fractions of 0.1, 0.2, and 0.3. In 28 patients with ARF, duplicate measurements were performed. In the lung model, an Fio(2) change of 0.1 resulted in a value of 103 +/- 5% of the reference FRC value of the lung model, and the precision was equally good up to an Fio(2) of 1.0 with a value of 103 +/- 7%. In the patients, duplicate measurements showed a bias of -5 mL with a 95% confidence interval [-38; 29 mL ]. A comparison of a change in Fio(2) of 0.1 with 0.3 showed a bias of -9 mL and limits of agreement of [-365; 347 mL]. This study shows good precision of FRC measurements with standard monitors using a change in Fio(2) of only 0.1. Measurements can be performed with equal precision up to an Fio(2) of 1.0.Keywords
This publication has 25 references indexed in Scilit:
- Alveolar pressure monitoring: an evaluation in a lung model and in patients with acute lung injuryIntensive Care Medicine, 2003
- Compliance Is Nonlinear over Tidal Volume Irrespective of Positive End-Expiratory Pressure Level in Surfactant-Depleted PigletsAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- A NEW METHOD TO ANALYZE LUNG COMPLIANCE WHEN PRESSURE–VOLUME RELATIONSHIP IS NONLINEARAmerican Journal of Respiratory and Critical Care Medicine, 1999
- The recording of FRC — is it of importance and can it be made simple?Intensive Care Medicine, 1993
- Open up the lung and keep the lung openIntensive Care Medicine, 1992
- Measurement of Lung Volume by Sulfur Hexafluoride Washout during Spontaneous and Controlled VentilationAnesthesiology, 1987
- Measurement of Functional Residual Capacity by Sulfur Hexafluoride WashoutAnesthesiology, 1985
- Shunt, Lung Volume and Perfusion during Short Periods of Ventilation with OxygenAnesthesiology, 1975
- Ventilation with end-expiratory pressure in acute lung diseaseJournal of Clinical Investigation, 1972