Calculation of induced current densities and specific absorption rates (SAR) for pregnant women exposed to hand-held metal detectors
- 22 July 2003
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (15) , 2551-2560
- https://doi.org/10.1088/0031-9155/48/15/319
Abstract
The finite difference time domain (FDTD) method in combination with a well established frequency scaling method was used to calculate the internal fields and current densities induced in a simple model of a pregnant woman and her foetus, when exposed to hand-held metal detectors. The pregnant woman and foetus were modelled using a simple semi-heterogeneous model in 10 mm resolution, consisting of three different types of tissue. The model is based on the scanned shape of a pregnant woman in the 34th gestational week. Nine different representative models of hand-held metal detectors operating in the frequency range from 8 kHz to 2 MHz were evaluated. The metal detectors were placed directly on the abdomen of the computational model with a spacing of 1 cm. Both the induced current density and the specific absorption rate (SAR) are well below the recommended limits for exposure of the general public published in the ICNIRP Guidelines and the IEEE C95.1 Standard. The highest current density is 8.3 mA m−2 and the highest SAR is 26.5 µW kg−1. Compared to the limits for the induced current density recommended in the ICNIRP Guidelines, a minimum safety factor of 3 exists. Compared to the IEEE C95.1 Standard, a safety factor of 60 000 for the specific absorption rate was found. Based on the very low specific absorption rate and an induced current density below the recommended exposure limits, significant temperature rise or nerve stimulation in the pregnant woman or in the foetus can be excluded.Keywords
This publication has 16 references indexed in Scilit:
- Calculation of induced current densities for humans by magnetic fields from electronic article surveillance devicesPhysics in Medicine & Biology, 2001
- Simulation of induced current densities in the human body at industrial induction heating frequenciesIEEE Transactions on Electromagnetic Compatibility, 1999
- Calculation of electric fields and currents induced in a millimeter-resolution human model at 60 Hz using the FDTD methodBioelectromagnetics, 1998
- Application of the finite difference time domain algorithm to quasi‐static field analysisRadio Science, 1997
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Some numerical methods for dosimetry: Extremely low frequencies to microwave frequenciesRadio Science, 1995
- Ethical Issues in Radiation Protection—The 1992 Sievert LectureHealth Physics, 1992
- Numerical dosimetry at power-line frequencies using anatomically based modelsBioelectromagnetics, 1992