Improved defibrillator waveform safety factor with biphasic waveforms
- 1 July 1983
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 245 (1) , H60-H65
- https://doi.org/10.1152/ajpheart.1983.245.1.h60
Abstract
Excitation thresholds and arrhythmias were studied in "adult-type" cultured chick embryo myocardial cells after electric field stimulation with biphasic, truncated, and rectified underdamped RLC (resistance-inductance-capacitance) type waveforms, to test the hypothesis that the negative phase of biphasic waveforms ameliorates membrane dysfunction induced by the initial positive portion. Photocell mechanograms and intracellular microelectrodes monitored extrasystoles and depolarization-induced arrhythmias. Rectifying or truncating biphasic waveforms did not alter the excitation threshold. However, shock intensities producing specific postshock arrhythmias or a specific severity of postshock prolonged depolarization differed significantly when biphasic waveforms were truncated or rectified. The voltage gradient producing a specific dysfunction was 12-14% lower for the truncated version than for the biphasic; that for the rectified version was 17-27% lower than for the biphasic version (although both contained the same energy). Safety factor, the ratio between shock intensity producing specific dysfunction and that producing excitation, was determined for each waveform. Biphasic waveforms had larger safety factors than truncated or rectified waveforms. Since safety factor, as measured in cultured myocardial cells, closely corresponds with in situ defibrillating effectiveness (14), the significantly higher safety factors of biphasic waveforms suggest that carefully shaped biphasic waveforms might improve the efficacy and safety of cardiac defibrillation procedures.This publication has 10 references indexed in Scilit:
- Determination of safety factor for defibrillator waveforms in cultured heart cellsAmerican Journal of Physiology-Heart and Circulatory Physiology, 1982
- ST-segment elevation with elective DC cardioversion.Circulation, 1981
- Therapeutic indices for transchest defibrillator shocks: Effective, damaging, and lethal electrical dosesAmerican Heart Journal, 1980
- Ultrastructural injury to chick myocardial cells in vitro following "electric countershock".Circulation Research, 1980
- Contour graph for relating per cent success in achieving ventricular defibrillation to duration, current, and energy content of shockAmerican Heart Journal, 1979
- Response of cultured myocardial cells to countershock-type electric field stimulationAmerican Journal of Physiology-Heart and Circulatory Physiology, 1978
- MYOCARDIAL DAMAGE AFTER REPETITIVE DIRECT-CURRENT SHOCK IN DOG - CORRELATION BETWEEN LEFT-VENTRICULAR END-DIASTOLIC PRESSURE AND EXTENT OF MYOCARDIAL NECROSIS1978
- Transthoracic ventricular defibrillation in the 100 kg calf with unidirectional rectangular pulses.Circulation, 1977
- Myocsrdial uptake of technetium-99m stannous pyrophosphate following direct current transthoracic countershock.Circulation, 1976
- Cardiac Arrhythmias Following Condenser Discharges and Their Dependence Upon Strength of Current and Phases of Cardiac CycleCirculation Research, 1963