Spurious counts and spurious results on haematology analysers: a review. Part I: platelets
Top Cited Papers
- 9 January 2007
- journal article
- review article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 29 (1) , 4-20
- https://doi.org/10.1111/j.1365-2257.2006.00870.x
Abstract
The widespread use of haematology analysers (HA) has led to a major improvement of cellular haematology, because of quick and accurate results found in most instances. However, in several situations, spurious results are observed. Inadequate blood samples, situations induced by the anticoagulant(s) used, peculiar changes related to the pathology in the patient, and technical considerations about performances of the various HA must be considered. Spurious thrombocytopenia occurs in several circumstances related to the presence of ethylenediamine tetra-acetic acid (EDTA) used as the anticoagulant. Mechanism of EDTA-dependent platelet (PLT) agglutination is related to circulating (auto)antibodies directed against normally hidden epitope(s) in the glycoprotein alpha IIb/beta IIIa complex from PLT membrane exposed only in the presence of EDTA. Other spuriously low PLT counts may be related to EDTA, including PLT rosetting around white blood cells (WBC; satellitism) and PLT-WBC aggregates, but mechanisms responsible for those latter phenomena are less well known. Spurious increase of PLT count may be related to several situations, including fragmented red blood cells, cytoplasmic fragments of nucleated cells, cryoglobulins, bacteria or fungi, and lipids. Flags generated in several of these situations alert the operator on possible abnormal findings and may identify the problem. Analysing only PLT parameters is not sufficient: in many situations the WBC differential scattergram is of crucial help for flagging. Flags generated depend on the software version on the HA used, the performance in detecting the same anomalies may differ according to which analyser is used, even those from the same manufacturer. Operators must be aware of the characteristics of their analyser and be able to recognize and circumvent anomalous results.Keywords
This publication has 101 references indexed in Scilit:
- Laboratory Identification of Cryoglobulinemia From Automated Blood Cell Counts, Fresh Blood Samples, and Blood FilmsAmerican Journal of Clinical Pathology, 2002
- Improved Platelet Counting Using Two-Dimensional Laser Light ScatterAmerican Journal of Clinical Pathology, 2000
- Association of pseudothrombocytopenia and pseudoleukopenia: Evidence for different pathogenic mechanismsScandinavian Journal of Clinical and Laboratory Investigation, 1994
- Clumping of lymphoma cells in peripheral blood induced by EDTA.Journal of Clinical Pathology, 1992
- Platelet satellitosis to polymorphonuclears: Cytochemical, immunological, and ultrastructural characterization of eight casesAmerican Journal of Hematology, 1991
- Platelet Clumping in Ph‐negative Myeloproliferative SyndromesActa Medica Scandinavica, 1987
- Platelet to Leukocyte Adherence PhenomenaActa Haematologica, 1982
- Pseudothrombocytopenia associated with vasculitisThe Lancet Healthy Longevity, 1980
- Spurious Thrombocytosis in Acute Myelocytic LeukemiaNew England Journal of Medicine, 1978
- Platelet satellitism and phagocytosis by neutrophils: Association with antiplatelet antibodies and lymphomaAmerican Journal of Hematology, 1977