The CDRH Helix: Anin vivoevaluation
- 1 January 1990
- journal article
- research article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 6 (1) , 241-252
- https://doi.org/10.3109/02656739009140819
Abstract
The Helix is an electromagnetic heating device used to induce regional/systemic hyperthermia for cancer therapy. It is a resonant device operating at about 82 MHz with an aperture size of 60 cm .times. 40 cm (elliptical) .times. 40 cm long. The Helix deposits power in tissues (or phantoms) by producing a predominantly axial electric field within its radiating aperture. Five pig experiments were performed to provide in vivo verification of specific absorption rate (SAR) measurements and electric field measurements which were obtained earlier in tissue-equivalent phantom and 0.9% saline, respectively. In addition to verifying the power deposition patterns found in phantoms, the pig experiments provided valuable insight into the capabilities and limitations of electromagnetic regional heating. For example, a kidney with limited blood flow, simulating a necrotic tumor, heated very well-although the highest temperature was not always measured there. Also, fat heating may be a problem, since excessive temperatures in the fat were observed in approximately 20% of the heatings. This paper compares the in vivo temperature measurements in pigs with SARs and electric field measurements obtained in phantoms, and also provides a brief overview of results of a Helix in clinical situations.This publication has 10 references indexed in Scilit:
- The CDRH HelixAmerican Journal of Clinical Oncology, 1989
- Quality-assurance reports: CDRH RF phantom for hyperthermia systems evaluationsInternational Journal of Hyperthermia, 1988
- Design of a clinical deep-body hyperthermia system based on the ‘coaxial TEM’ applicatorInternational Journal of Hyperthermia, 1987
- Regional hyperthermia: A feasibility analysisInternational Journal of Hyperthermia, 1987
- Abdominal regional hyperthermia with an annular phased array.Journal of Clinical Oncology, 1986
- Results of a Phase I regional hyperthermia device evaluation: Microwave annular array versus radio frequency induction coilInternational Journal of Hyperthermia, 1986
- A comparison of deep regional hyperthermia from an annular array and a concentric coil in the same patientsInternational Journal of Radiation Oncology*Biology*Physics, 1985
- Development of a Family of RF Helical Coil Applicators Which Produce Transversely Uniform Axially Distributed Heating in Cylindrical Fat-Muscle PhantomsIEEE Transactions on Biomedical Engineering, 1984
- A New Coaxial TEM Radiofrequency/Microwave Applicator for Non-Invasive Deep-Body HyperthermiaJournal of Microwave Power, 1983