Error Analysis of Simple Algorithms for Determining Fluorescence Lifetimes in Ultradilute Dye Solutions
- 1 March 1994
- journal article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 48 (3) , 400-405
- https://doi.org/10.1366/0003702944028191
Abstract
We have evaluated the use of two simple algorithms for determining the decay parameters describing a single exponential process for dyes with nanosecond and subnanosecond fluorescence lifetimes in the limit of low concentrations and high backgrounds from scattered photons generated by the solvent using experimental and Monte Carlo simulation results. These algorithms, the maximum likelihood estimator (MLE) and the rapid lifetime determination (RLD), are computationally easy to perform, allowing the evaluation of large amounts of data quickly and efficiently. The MLE and RLD methods were used to calculate the fluorescence lifetimes of three near-IR dyes with lifetimes spanning the range of 0.57 ns to 1.12 ns. For low-concentration conditions and high background-to-fluorescence ratios, the MLE method resulted in larger errors when compared to RLD, although both methods yielded comparable standard deviations. However, when the interval over which the lifetime was calculated within the decay profile was shifted to latter times in order to reduce the amount of scattered photons included in the calculation, significant improvements in the accuracy were observed with the use of MLE. Shifting the start channel of the calculation to latter time channels within the decay profile did not affect the lifetime with the use of RLD. Inclusion of large amounts of scattering photons was found to bias the calculated lifetime to lower values, reducing the accuracy of the determination. The relative standard deviations for MLE and RLD were found to be approximately 2–3% at a background-to-fluorescence ratio of 0.5. The absolute relative error in the methods at the 0.50 background-to-fluorescence ratio ranged from 14 to 27% for MLE and 8 to 18% for the RLD method when the calculation was initiated at t = 0. This error was found to decrease to < 1% with the use of MLE when the calculation was initiated at t ≈ 100 ps.Keywords
This publication has 34 references indexed in Scilit:
- Proton charge transfer involving the water solventThe Journal of Physical Chemistry, 1991
- Development of a streak-camera-based time-resolved microscope fluorometer and its application to studies of membrane fusion in single cellsBiochemistry, 1991
- Adsorbate reorientation at a water/(octadecylsilyl)silica interfaceAnalytical Chemistry, 1991
- Lifetime-selective fluorescence imaging using an rf phase-sensitive cameraReview of Scientific Instruments, 1991
- Construction and evaluation of a frequency-domain epifluorescence microscope for lifetime and anisotropy decay measurements in subcellular domainsBiophysical Chemistry, 1991
- A Two-Dimensional Fluorescence Lifetime Imaging System Using a Gated Image IntensifierApplied Spectroscopy, 1991
- Photoluminescence lifetime microscope spectrometer based on time-correlated single-photon counting with an avalanche diode detectorReview of Scientific Instruments, 1990
- Effects of molecular organization on photophysical behavior: steady-state and real-time behavior of chlorophyll a fluorescence in spread monolayers of dipalmitoylphosphatidylcholineThe Journal of Physical Chemistry, 1988
- Measurement of fluorescence lifetimes during liquid chromatographyAnalytical Chemistry, 1987
- THE PHOTOPHYSICS AND PHOTOCHEMISTRY OF THE NEAR‐UV ABSORBING AMINO ACIDS–I. TRYPTOPHAN AND ITS SIMPLE DERIVATIVESPhotochemistry and Photobiology, 1984