Lifetime-selective fluorescence imaging using an rf phase-sensitive camera
- 1 July 1991
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (7) , 1727-1734
- https://doi.org/10.1063/1.1142413
Abstract
We report the creation of two‐dimensional fluorescence lifetime images, based on a sinusoidally modulated image intensifier that is operated as a radio‐frequency phase‐sensitive camera, synchronized to a mode‐locked and cavity dumped picosecond dye laser. By combining the image intensifier with a CCD camera and applying digital image processing, lifetime‐selective signal suppression can be realized even for fluorophores with comparable lifetimes. This phase‐sensitive technique can be used to create fluorescence lifetime images, that is, images in which the contrast is based upon the fluorescence lifetimes rather than upon local probe concentration and/or intensity. Because the lifetimes of many dyes are sensitive to the chemical environments surrounding the fluorophore, fluorescence lifetime imaging (FLIM) can reveal the local chemical composition and properties of the molecular environment that surrounds the fluorophore. As an example we created images of rhodamine 6G (4 ns) and rhodamine B (1.5 ns) solutions in which the difference in lifetimes results in 100% contrast, whereas the total fluorescence intensity is similar. In order to estimate the time resolution obtainable with our phase‐sensitive imaging setup, we also performed measurements using distance‐selective suppression of optical signals backscattered from laser‐illuminated targets. In these studies, we have created distance‐selective images with a resolution of 3.75 cm, which corresponds to a lifetime resolution of 0.25 ns for fast‐decaying fluorophores. Since we observed nearly 100% contrast for this 0.25 ns difference, still smaller distances and/or lifetime differences could be observed, which seems to imply some advantages of phase fluorometric lifetime imaging. Using these same intensifiers in the pulse‐gating mode one expects a typical 5 ns gating time, which result in a distance resolution of only 75 cm. The distance‐selective imaging principle has the potential for manifold applications related to robotics, construction, and even to spacecraft maneuvering. Fluorescence lifetime imaging, in combination with fluorescence microscopy, can have numerous applications to biochemistry, biophysics, and cell physiology.Keywords
This publication has 37 references indexed in Scilit:
- Luminescent barometry in wind tunnelsReview of Scientific Instruments, 1990
- Time-Resolved Fluorescence Microscopy Using Multichannel Photon CountingApplied Spectroscopy, 1990
- DETECTION OF LATENT FINGERPRINTS BY LASER-EXCITED LUMINESCENCEAnalytical Chemistry, 1989
- PICOSECOND FLUORESCENCE SPECTROSCOPY ON INCORPORATION PROCESSES OF HEMATOPORPHYRIN DERIVATIVE INTO MALIGNANT TUMOR CELLSin vitroPhotochemistry and Photobiology, 1988
- A FLUORESCENCE IMAGING DEVICE FOR ENDOSCOPIC DETECTION OF EARLY STAGE CANCER – INSTRUMENTAL and EXPERIMENTAL STUDIESPhotochemistry and Photobiology, 1987
- Laser excited fluorescence of hematoporphyrin derivative for diagnosis of cancerIEEE Journal of Quantum Electronics, 1984
- Laser Detection of Latent Fingerprints: Treatment with Glue Containing Cyanoacrylate EsterJournal of Forensic Sciences, 1983
- New technique of surface flow visualization based on oxygen quenching of fluorescenceReview of Scientific Instruments, 1980
- Quenching of fluorescence by oxygen. Probe for structural fluctuations in macromoleculesBiochemistry, 1973
- Quenching of luminescence by oxygenTransactions of the Faraday Society, 1939