Malleability of the Ocular Surface in Response to Mechanical Stress Induced by Orthokeratology Contact Lenses
- 1 February 2008
- journal article
- Published by Wolters Kluwer Health in Cornea
- Vol. 27 (2) , 133-141
- https://doi.org/10.1097/ico.0b013e318158b4b5
Abstract
To determine the malleability of the ocular surface by examining the acute effects of local mechanical stress on optical performance, corneal shape, and corneal/epithelial thickness after corneal refractive therapy for myopia and hyperopia (CRT and CRTH). Twenty ametropes (spherical equivalent: -2.08 +/- 2.31 D) wore CRT and CRTH lenses in a random order on 1 eye (randomly selected). The lenses were worn for 15, 30, and 60 minutes (randomly ordered, with each period taking place on a different day). Refractive error, aberrations, corneal topography, and corneal/epithelial thickness (using OCT) were measured before and after lens wear. The measurements were performed on the control eyes at the 60-minute visit only. With both CRT and CRTH lens wear, significant changes occurred in many parameters from the 15-minute time point. The refractive error and defocus decreased after CRT lens wear (all P < 0.05) and increased after CRTH lens wear from baseline (all P < 0.05). Astigmatism did not change (both P > 0.05). Higher-order aberrations, including coma and spherical aberration (SA), increased after CRT and CRTH lens wear (all P < 0.05) from baseline, but the signed SA shifted from positive to negative after CRTH lens wear (P < 0.05). The central cornea flattened and the midperiphery steepened after CRT lens wear, whereas the central cornea steepened and paracentral region flattened after CRTH lens wear (P < 0.05). The central cornea swelled less than the midperiphery after CRT lens wear (P < 0.05), whereas the central cornea swelled more than the paracentral region after CRTH lens wear (P < 0.05). The central epithelium was thinner than the midperiphery after CRT lens wear (P < 0.05) and thicker than the paracentral region after CRTH lens wear (P < 0.05). Optical performance, corneal curvature, and epithelial thickness did not change from baseline in the control eyes (all P > 0.05). CRT lenses for myopia and hyperopia induce significant structural and optical changes in as little as 15 minutes. The cornea, particularly the epithelium, is remarkably malleable, with rapid steepening and flattening possible in little time.Keywords
This publication has 41 references indexed in Scilit:
- Corneal Refractive Therapy with Different Lens Materials, Part 2: Effect of Oxygen Transmissibility on Corneal Shape and Optical CharacteristicsOptometry and Vision Science, 2007
- Corneal Shape and Optical Performance After One Night of Corneal Refractive Therapy for HyperopiaOptometry and Vision Science, 2007
- Overnight Orthokeratology Lens Wear Can Inhibit the Central Stromal Edema ResponseInvestigative Opthalmology & Visual Science, 2005
- Overnight OrthokeratologyEye & Contact Lens: Science & Clinical Practice, 2004
- Comparison of Reverse-Geometry Lens Designs for Overnight OrthokeratologyOptometry and Vision Science, 2003
- Overnight OrthokeratologyEye & Contact Lens: Science & Clinical Practice, 2003
- Practice of orthokeratology by a group of contact lens practitioners in Hong KongClinical and Experimental Optometry, 2003
- An analysis of the changes in corneal shape and refractive error induced by accelerated orthokeratologyInternational Contact Lens Clinic, 1997
- Strip Extensiometry for Comparison of the Mechanical Response of Bovine, Rabbit, and Human CorneasJournal of Biomechanical Engineering, 1992
- Squeeze Forces in Contact Lenses with a Steep Base Curve RadiusOptometry and Vision Science, 1980