Fractional Flow Reserve
- 1 December 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 92 (11) , 3183-3193
- https://doi.org/10.1161/01.cir.92.11.3183
Abstract
Background Fractional flow reserve (FFR), defined as the ratio of maximum flow in the presence of a stenosis to normal maximum flow, is a lesion-specific index of stenosis severity that can be calculated by simultaneous measurement of mean arterial, distal coronary, and central venous pressure (P a , P d , and P v , respectively), during pharmacological vasodilation. The aims of this study were to define ranges of FFR values, whether associated with inducible ischemia or not, and to investigate FFR in normal coronary arteries. Methods and Results In 60 patients accepted for percutaneous transluminal coronary angioplasty (PTCA) of single-vessel disease, with a positive exercise test (ET) a was measured by the guiding catheter, P d by an 0.018-in fiber-optic pressure-monitoring wire, and P v by a multipurpose catheter. The ET was repeated after 5 to 7 days, and only if this second ET had reverted to normal was the pre-PTCA value of FFR definitely considered to be associated with inducible ischemia and the post-PTCA value not. Myocardial FFR (FFR myo ) increased from 0.53±0.15 before PTCA to 0.88±0.07 after PTCA. Coronary FFR increased from 0.38±0.19 to 0.83±0.12. In all patients, values of FFR myo definitely associated with ischemia were ≤0.74, whereas all except two values not associated with inducible ischemia exceeded 0.74. Moreover, FFR myo in 18 coronary arteries in 5 normal patients equaled 0.98±0.03. Conclusions A value of FFR myo of 0.74 reliably discriminates coronary stenosis, whether associated with inducible ischemia or not. Therefore, FFR myo is a useful index to determine the functional significance of an epicardial coronary stenosis and may facilitate clinical decision making in patients with an equivocal coronary stenosis.Keywords
This publication has 40 references indexed in Scilit:
- Effects of heart rate on phasic coronary blood flow pattern and flow reserve in patients with normal coronary arteries: A study with an intravascular Doppler catheter and spectral analysisAmerican Heart Journal, 1994
- High-fidelity translesional pressure gradients during percutaneous transluminal coronary angioplasty: Correlation with quantitative coronary angiographyAmerican Heart Journal, 1993
- Serious ventricular dysrhythmias after intracoronary papaverineThe American Journal of Cardiology, 1988
- Normalization of coronary flow reserve by percutaneous transluminal coronary angioplastyThe American Journal of Cardiology, 1988
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Maximal coronary flow and the concept of coronary vascular reserve.Circulation, 1984
- Does Visual Interpretation of the Coronary Arteriogram Predict the Physiologic Importance of a Coronary Stenosis?New England Journal of Medicine, 1984
- Angiographic prevalence of high-risk coronary artery disease in patient subsets (CASS).Circulation, 1981
- Physiologic basis for assessing critical coronary stenosisThe American Journal of Cardiology, 1974
- Measurement of Coronary Sinus Blood Flow by Continuous Thermodilution in ManCirculation, 1971