Comparison of Low Rate Dual Chamber Pacing to Activity Responsive Rate Variable Ventricular Pacing
- 1 May 1990
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 13 (5) , 646-652
- https://doi.org/10.1111/j.1540-8159.1990.tb02082.x
Abstract
A study was undertaken to evaluate exercise performance in 18 dual chamber pacemaker patients believed to be chronotropically incompetent. All patients were paced in a DDD AV synchronous mode of 80 beats per minute (beats/mm) as well as an externally triggered, activity responsive VVIR mode. Patients underwent two single blind, randomized symptom‐limited treadmill tests (Sheffield protocol). Four of the 18 patients achieved intrinsic rates > 100 beats/min and were deleted from the primary study. If was noted that all four of these patients performed best with intrinsic rate response and AV synchrony. Thirteen of the remaining 14 patients demonstrated improved exercise tolerance in the WIR mode. Average exercise time in the WIR mode (7:25 ± 3:12 min) was significantly greater (P < 0.05) than the DDD mode (6:01 ± 2:27 min). Work performed was significantly greater (P < 0.05) in the VVIR mode (4.77 ± 1.97 METS) than in the DDD mode (3.78 ± 0.77 METS). Maximum heart rates were 83.86 ± 5.11 beats/min in DDD mode versus 116.00 ± 30.56 beats/min in VVIR mode. The results demonstrated that improved exercise tolerance can be achieved with single chamber rate variable pacing compared to DDD pacing in patients with chronotropic incompetence. However, potential symptoms associated with loss of AV synchrony should be ruled out.Keywords
This publication has 19 references indexed in Scilit:
- Physiological Pacing: Present Status and Future DevelopmentsPacing and Clinical Electrophysiology, 1987
- Rate Adaptive Pacing—Clinical Experience with Three Different Pacing SystemsPacing and Clinical Electrophysiology, 1986
- Clinical Experience with an Activity Sensing Pacemaker.Pacing and Clinical Electrophysiology, 1986
- Sensors in PacingPacing and Clinical Electrophysiology, 1986
- Trends in Pacemakers Which Physiologically Increase Rate: DDD and Rate Responsive.Pacing and Clinical Electrophysiology, 1986
- Holter-Monitored Heart Rhythm During Atrioventricular Synchronous and Fixed-Rate Ventricular PacingPacing and Clinical Electrophysiology, 1986
- Rate‐Responsive Pacing: Clinical ExperiencePacing and Clinical Electrophysiology, 1985
- Critical Analysis of Sensors for Physiological Responsive PacingPacing and Clinical Electrophysiology, 1984
- Atrial Synchronized Ventricular Pacing: Contribution of the Chronotropic Response to Improved Exercise PerformancePacing and Clinical Electrophysiology, 1983
- Comparison of Resting Hemodynamic Indices and Exercise Performance During Atrial Synchronized and Asynchronous Ventricular PacingPacing and Clinical Electrophysiology, 1983