Mode purity measurements on gyrotrons for plasma heating at the stellarator W VII-AS
- 1 January 1988
- journal article
- research article
- Published by Taylor & Francis in International Journal of Electronics
- Vol. 64 (1) , 21-28
- https://doi.org/10.1080/00207218808962781
Abstract
For electron cyclotron resonance heating of plasmas in the stellarator W VII-AS, high-power microwave sources with high mode purity are needed. Therefore, the mode compositions of four commercial 200 kW/70 GHz gyrotrons, specified for this project, were analysed with a wave number spectrometer. The measurements confirm the specified spurious mode content of less than 10%.Keywords