A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling
Top Cited Papers
Open Access
- 29 October 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (5) , 1020-1027
- https://doi.org/10.1002/mrm.21403
Abstract
Arterial spin labeling (ASL) is capable of noninvasively measuring blood flow by magnetically tagging the protons in arterial blood, which has been conventionally achieved using instantaneous (PASL) or continuous (CASL) RF pulses. As an intermediate method, pseudocontinuous ASL (pCASL) utilizes a train of discrete RF pulses to mimic continuous tagging that is often unavailable on imagers due to the requirement of continuous RF transmit capabilities. In the present study, we implemented two versions of pCASL (balanced and unbalanced gradient waveforms in tag and control scans) for both transmit/receive coils and array receivers. Experimental data show a 50% ± 4% increase of signal‐to‐noise ratio (SNR) compared with PASL and a higher tagging efficiency than amplitude‐modulated (AM) CASL (80% vs. 68%). Computer simulations predict an optimal tagging efficiency of 85% for flow velocities from 10 to 60 cm/s. It is theoretically and experimentally demonstrated that the tagging efficiency of pCASL is dependent upon the resonance offset and flip angle of the RF pulse train. We conclude that pCASL has the potential of combining the merits of PASL, including less hardware demand and higher tagging efficiency, and CASL, which includes a longer tagging bolus and thus higher SNR. These improvements provide a better balance between tagging efficiency and SNR. Magn Reson Med 58:1020–1027, 2007.Keywords
This publication has 27 references indexed in Scilit:
- An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigationNMR in Biomedicine, 2006
- Quantification of Blood Flow in Brain Tumors: Comparison of Arterial Spin Labeling and Dynamic Susceptibility-weighted Contrast-enhanced MR ImagingRadiology, 2003
- H215O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humansMagnetic Resonance in Medicine, 2000
- Quantification of cerebral blood flow by bolus tracking and artery spin tagging methodsMagnetic Resonance Imaging, 2000
- Transfer insensitive labeling technique (TILT): Application to multislice functional perfusion imagingJournal of Magnetic Resonance Imaging, 1999
- Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labelingNMR in Biomedicine, 1997
- Mr perfusion studies with t1‐weighted echo planar imagingMagnetic Resonance in Medicine, 1995
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.Radiology, 1994
- Radioactive microsphere validation of a volume localized continuous saturation perfusion measurementMagnetic Resonance in Medicine, 1994