Dose to cardiologists in haemodynamic and electrophysiology cardiac interventional procedures
- 1 December 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 117 (1-3) , 111-115
- https://doi.org/10.1093/rpd/nci764
Abstract
Interventional cardiac procedures can be complex and involve extensive use of low dose rate fluoroscopy and high dose rate in image acquisition mode; hence, staff may receive significant radiation exposure. Radiation exposure to operators was assessed in 173 procedures. Fluoroscopy time, number of acquired images and dose–area product were recorded and occupational dose assessed with thermoluminescence dosemeters. The effective dose to the operator was compared with relevant literature data: values found were generally lower than those reported for other interventional cardiology laboratories. This is probably because of the strict radiation protection policy in our centre. Higher effective doses were found for defibrillator implantation and percutaneous transluminal coronary angiography procedures; for other cardiac procedures, effective dose was lower. Yearly extrapolated occupational doses to cardiologists are lower than the regulatory dose limit and in the lower band of doses reported in the literature.Keywords
This publication has 16 references indexed in Scilit:
- Radiation exposure to cardiologists performing interventional cardiology proceduresEuropean Journal of Radiology, 2003
- Radiation Exposure During Radiofrequency Catheter Ablation for Atrial FibrillationPacing and Clinical Electrophysiology, 2003
- Radiation exposure to medical staff in interventional and cardiac radiology.The British Journal of Radiology, 1998
- The interdependence of staff and patient doses in interventional radiology.The British Journal of Radiology, 1997
- Staff dose reduction during coronary angiography using low framing speedThe British Journal of Radiology, 1996
- The Estimation of Occupational Effective Dose in Diagnostic Radiology With Two DosimetersHealth Physics, 1994
- Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.Circulation, 1994
- Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachycardiaThe American Journal of Cardiology, 1992
- Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections.Circulation, 1991
- Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratoryJournal of the American College of Cardiology, 1990