A new method to calculate aortic valve area without left heart catheterization.
- 1 December 1984
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 70 (6) , 978-983
- https://doi.org/10.1161/01.cir.70.6.978
Abstract
Assessment of the severity of aortic stenosis remains a commonly encountered clinical problem. Noninvasive evaluation has to date not proven sufficiently accurate in most cases to permit clinical decision making in the individual patient. Therefore, cardiac catheterization and measurement of the valve area with use of the Gorlin equation remains the standard approach in patients with suspected aortic stenosis. Doppler ultrasound allows direct measurement of blood velocity in cardiac chambers. This technique was used to study 16 patients with suspected aortic stenosis after cardiac catheterization. Aortic valve area (AVA) was calculated with the equation AVA = CO/(SEP X mean velocity), where CO is cardiac output measured by thermodilution and SEP is the systolic ejection period derived from the Doppler tracings. The resulting value was compared with valve area calculated from cardiac catheterization data and an excellent correlation was noted (r = .99). This study demonstrates that Doppler ultrasound can be used to accurately measure aortic valve area without the need for left heart catheterization.This publication has 14 references indexed in Scilit:
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IPublished by Elsevier ,2004
- Doppler ultrasound measurement of cardiac output in patients with physiologic pacemakersThe American Journal of Cardiology, 1984
- Noninvasive quantification of stenotic semilunar valve areas by doppler echocardiographyJournal of the American College of Cardiology, 1984
- Noninvasive determination of pressure gradients in children: Two methods employing pulsed Doppler echocardiographyJournal of the American College of Cardiology, 1984
- Evaluation of aortic stenosis by continuous wave Doppler ultrasoundJournal of the American College of Cardiology, 1984
- Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast fourier transform spectral analysisThe American Journal of Cardiology, 1982
- Non-invasive assessment of aortic stenosis by Doppler ultrasound.Heart, 1980
- Aortic stenosis: Echocardiographic cusp separation and surgical description of aortic valve in 22 patientsThe American Journal of Cardiology, 1977
- Systolic-Time IntervalsNew England Journal of Medicine, 1977
- Determination of Pressure Gradient in Mitral Stenosis with a Non‐invasive Ultrasound Doppler TechniqueActa Medica Scandinavica, 1976