The influence of stress conditions on the wear of UHMWPE for total joint replacements
- 1 January 1997
- journal article
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 8 (10) , 603-611
- https://doi.org/10.1023/a:1018515318630
Abstract
In vitro studies of the effect of contact stress on the wear of ultra high molecular weight polyethylene (UHMWPE) in orthopaedic applications have produced contradictory results which predict both increased and decreased wear with increasing contact stress. In vivo studies of functioning hip prostheses have reported that 22 mm femoral heads generate lower linear and volumetric wear rates than 32 mm femoral heads. The effect of decreasing the head size will increase the contact stress but decrease the sliding distance per motion cycle. The present study consists of wear experiments under a range of contact stress magnitudes and application conditions in order to simulate the wear processes occurring in vivo. The results from these tests indicated that the wear factor actually decreases with increasing contact stress if the stress was not varied with time. If a time dependent or spatially varying stress was applied, the wear factor can increase greatly when compared to similar magnitude constant contact stress. This effect may be due to the complex relationship between the rate of wear particle generation and the rate at which the particles are released from the interface. The results of these wear experiments are discussed in terms of the influence of the stress conditions upon potential wear processes in total hip and knee prostheses.Keywords
This publication has 11 references indexed in Scilit:
- Ultra-High Molecular Weight Polyethylene Wear Debris Generated in Vivo and in Laboratory Tests; the Influence of Counterface RoughnessProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- The origin of submicron polyethylene wear debris in total hip arthroplasty.1995
- Isolation and characterization of debris in membranes around total joint prostheses.Journal of Bone and Joint Surgery, 1994
- A parametric analysis of the contact stress in ultra-high molecular weight polyethylene acetabular cupsMedical Engineering & Physics, 1994
- The Dominance of Cyclic Sliding in Producing Wear in Total Knee ReplacementsClinical Orthopaedics and Related Research, 1991
- Effect of femoral head size on wear of the polyethylene acetabular component.Journal of Bone and Joint Surgery, 1990
- The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.Journal of Bone and Joint Surgery, 1986
- Contact pressure dependence of wear rates of ultra high molecular weight polyethyleneJournal of Biomedical Materials Research, 1979
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977
- The mechanics of the knee joint in relation to normal walkingJournal of Biomechanics, 1970