Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods
- 1 November 1996
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 14 (6) , 888-894
- https://doi.org/10.1002/jor.1100140607
Abstract
The role of different loading conditions on resorption of plasma‐sprayed hydroxyapatite coating was investigated in an experimental study. Resorption of hydroxyapatite was quantified by histomorphometric and stereological methods on backscattered scanning electron images. Hydroxyapatite‐coated titanium implants were inserted unilaterally into the medial femoral condyle of the knee in 14 mature dogs. Initially, all implants were subjected to controlled micromotion of 150 μm. After 4 weeks, the dogs were randomly assigned either to have the implant surgically immobilized to prevent further micromovement or to have a sham operation. Sixteen weeks after the first operation, the implants were analyzed. Six noninserted implants served as controls. The surface area and volume of the hydroxyapatite coating were reduced on the immobilized implants by 53 and 67% (p < 0.05), respectively, and were further significantly reduced on the continuously loaded implants by 83 and 87%, respectively, compared with the control implants. The hydroxyapatite coating was significantly thinner on immobilized (15 μm) and continuously loaded (15 μm) implants as compared with control implants (23 μm), but no difference between the inserted implants was found. Areas not covered with hydroxyapatite had 29 and 24% bone coverage on the immobilized and continuously loaded implants (not significant). Resorption of hydroxyapatite coating did occur in vivo. Continuous loading of the implants accelerated resorption significantly compared with immobilization of the implants. It is suggested that completely resorbed hydroxyapatite was partly replaced by bone in direct contact with the metal implant surface.Keywords
This publication has 34 references indexed in Scilit:
- Femoral component migration in total knee arthroplasty: Randomized study comparing cemented and uncemented fixation of the Miller‐Galante I designJournal of Orthopaedic Research, 1995
- In vivo mechanical and histological characteristics of HA‐coated implants vary with coating vendorJournal of Biomedical Materials Research, 1995
- Bone response to hydroxyapatite‐coated and commercially pure titanium implants in the human arthritic kneeJournal of Orthopaedic Research, 1994
- A Double-Blind Study of 250 Cases Comparing Cemented With Cementless Total Hip ArthroplastyPublished by Wolters Kluwer Health ,1994
- Complications With Hydroxyapatite Participate Separation in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1994
- Studies of the solubility of different calcium phosphate ceramic particles in vitroBiomaterials, 1990
- Coatings of Ceramics on MetalsAnnals of the New York Academy of Sciences, 1988
- Some new, simple and efficient stereological methods and their use in pathological research and diagnosisAPMIS, 1988
- The effects of mechanical stability on the macromolecules of the connective tissue matrices produced during fracture healing. I. The collagensJournal of Molecular Histology, 1986
- Biodegradation behavior of various calcium phosphate materials in bone tissueJournal of Biomedical Materials Research, 1983