Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures
- 8 February 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (5) , 1101-1112
- https://doi.org/10.1088/0031-9155/51/5/003
Abstract
Our goal was to develop a method for generating high-resolution three-dimensional pulmonary compliance images in rodents from computed tomography (CT) images acquired at a series of constant pressures in ventilated animals. One rat and one mouse were used to demonstrate this technique. A pre-clinical GE flat panel CT scanner (maximum 31 line-pairs cm(-1) resolution) was utilized for image acquisition. The thorax of each animal was imaged with breath-holds at 2, 6, 10, 14 and 18 cm H2O pressure in triplicate. A deformable image registration algorithm was applied to each pair of CT images to map corresponding tissue elements. Pulmonary compliance was calculated on a voxel by voxel basis using adjacent pairs of CT images. Triplicate imaging was used to estimate the measurement error of this technique. The 3D pulmonary compliance images revealed regional heterogeneity of compliance. The maximum total lung compliance measured 0.080 (+/-0.007) ml air per cm H2O per ml of lung and 0.039 (+/-0.004) ml air per cm H2O per ml of lung for the rat and mouse, respectively. In this study, we have demonstrated a unique method of quantifying regional lung compliance from 4 to 16 cm H2O pressure with sub-millimetre spatial resolution in rodents.Keywords
This publication has 29 references indexed in Scilit:
- Potential Applications of Flat-Panel Volumetric CT in Morphologic, Functional Small Animal ImagingNeoplasia, 2005
- Quantification of regional ventilation from treatment planning CTInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Murine Lung Tumor Measurement Using Respiratory-Gated Micro-Computed TomographyInvestigative Radiology, 2005
- The protective effect of recombinant human keratinocyte growth factor on radiation-induced pulmonary toxicity in ratsInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Lung imaging of laboratory rodents in vivoPublished by SPIE-Intl Soc Optical Eng ,2004
- Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow methodPhysics in Medicine & Biology, 2004
- Assessment of the pulmonary structure-function relationship and clinical outcomes measures: Quantitative volumetric CT of the lungAcademic Radiology, 1997
- The computation of optical flowACM Computing Surveys, 1995
- Biological magnetic resonance imaging using laser-polarized 129XeNature, 1994
- THE VISCO‐ELASTIC PROPERTIES OF THE LUNGSQuarterly Journal of Experimental Physiology and Cognate Medical Sciences, 1939