Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up
Top Cited Papers
Open Access
- 28 January 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (5) , 639-644
- https://doi.org/10.1093/europace/eut417
Abstract
BackgroundThe novel cryoballoon Advance (CB-A) has proven to achieve significantly lower temperatures and faster pulmonary vein isolation (PVI) times in comparison with the first-generation device. Although acutely very effective, to the best of our knowledge, data on mid-term clinical follow-up is lacking.AimsThe aim of the study was to analyse the freedom from recurrence of atrial fibrillation (AF) on a 1-year follow-up period, in a series of consecutive patients having undergone PVI with the CB-A for paroxysmal AF (PAF).Methods and resultsForty-two patients [30 male (71%); mean age: 57.9 ± 21.1 years] were included. All patients underwent a procedure with the large 28 mm CB-A. A total 168 PVs were depicted on the pre-procedural computed tomography scan. All PVs (100%) could be isolated with the CB only. The freedom from AF off-antiarrhythmic drug treatment after a single procedure was 78% of patients at a mean 11.6 ± 2.0 months follow-up. If considering a blanking period (BP) of 3 months, success rate was 83%. Phrenic nerve palsy (PNP) was the most frequent complication occurring in 19% of individuals.ConclusionThe CB-A is very effective in producing PVI and affords freedom from AF at 12 months follow-up in 83% of patients affected by drug-resistant PAF following a 3-month BP. The most frequent complication observed was PNP which occurred in 19% of patients. All PNP reverted during follow-up.Keywords
This publication has 17 references indexed in Scilit:
- Increased Incidence of Esophageal Thermal Lesions Using the Second-Generation 28-mm CryoballoonCirculation: Arrhythmia and Electrophysiology, 2013
- Improved In Vivo Performance of Second‐Generation Cryoballoon for Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2013
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJournal of the American College of Cardiology, 2013
- Long-Term Outcomes After Cryoballoon Pulmonary Vein IsolationJournal of the American College of Cardiology, 2013
- Pulmonary Vein Isolation Using a Second‐Generation Cryoballoon Catheter: A Randomized Comparison of Ablation Duration and Method of DeflationJournal of Cardiovascular Electrophysiology, 2013
- Cryoballoon ablation of paroxysmal atrial fibrillation: 5-year outcome after single procedure and predictors of successEP Europace, 2013
- Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation CryoballoonJournal of Cardiovascular Electrophysiology, 2012
- Verification of pulmonary vein isolation during single transseptal cryoballoon ablation: a comparison between the classical circular mapping catheter and the inner lumen mapping catheterEP Europace, 2012
- Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablationEP Europace, 2010
- Circumferential Pulmonary Vein Isolation With the Cryoballoon TechniqueJournal of the American College of Cardiology, 2008